Measuring interfractional and intrafractional motion with cone beam computed tomography and an optical localization system for lower extremity soft tissue sarcoma patients treated with preoperative intensity-modulated radiation therapy
- PMID: 20350788
- DOI: 10.1016/j.ijrobp.2009.09.054
Measuring interfractional and intrafractional motion with cone beam computed tomography and an optical localization system for lower extremity soft tissue sarcoma patients treated with preoperative intensity-modulated radiation therapy
Abstract
Purpose: To evaluate inter- and intrafractional motion and rotational error for lower extremity soft tissue sarcoma patients by using cone beam computed tomography (CBCT) and an optical localization system.
Methods and materials: Thirty-one immobilized patients received CBCT image-guided intensity-modulated radiation therapy. Setup deviations of >3 mm from the planned isocenter were corrected. A second CBCT acquired before treatment delivery was registered to the planning CT to estimate interfractional setup error retrospectively. Interfractional error and rotational error were calculated in the left-right (LR), superoinferior (SI), and anteroposterior (AP) dimensions. Intrafractional motion was assessed by calculating the maximum relative displacement of optical localization system reflective markers placed on the patient's surface, combined with pre- and postfraction CBCT performed for 17 of the 31 patients once per week. The overall systematic error (SE) and random error (RE) were calculated for the interfractional and intrafractional motion for planning target volume margin calculation.
Results: The standard deviation (SD) of the interfractional RE was 1.9 mm LR, 2.1 mm SI, and 1.8 mm AP, and the SE SD was 0.6 mm, 1.2 mm, and 0.7 mm in each dimension, respectively. The overall rotation (inter- and intrafractional) had an RE SD of 0.8° LR, 1.7° SI, and 0.7° AP and an SE SD of 1.1° LR, 1.3° SI, and 0.3° AP. The SD of the overall intrafractional RE was 1.6 mm LR, 1.6 mm SI, and 1.4 mm AP, and the SE SD was 0.7 mm AP, 0.6 mm SI, and 0.6 mm AP.
Conclusions: A uniform 5-mm planning target volume margin was quantified for lower extremity soft tissue sarcoma patients and has been implemented clinically for image-guided intensity-modulated radiation therapy.
Copyright © 2010 Elsevier Inc. All rights reserved.
Similar articles
-
Adaptive radiotherapy and the dosimetric impact of inter- and intrafractional motion on the planning target volume for prostate cancer patients.Strahlenther Onkol. 2020 Jul;196(7):647-656. doi: 10.1007/s00066-020-01596-x. Epub 2020 Mar 10. Strahlenther Onkol. 2020. PMID: 32157345 Free PMC article.
-
Superiority of a soft tissue-based setup using cone-beam computed tomography over a bony structure-based setup in intensity-modulated radiotherapy for prostate cancer.J Appl Clin Med Phys. 2015 Sep 8;16(5):239–245. doi: 10.1120/jacmp.v16i5.5448. J Appl Clin Med Phys. 2015. PMID: 26699304 Free PMC article.
-
Tumor motion changes in stereotactic body radiotherapy for liver tumors: an evaluation based on four-dimensional cone-beam computed tomography and fiducial markers.Radiat Oncol. 2017 Mar 23;12(1):61. doi: 10.1186/s13014-017-0799-7. Radiat Oncol. 2017. PMID: 28335794 Free PMC article.
-
Intrafractional motion management in external beam radiotherapy.J Xray Sci Technol. 2019;27(6):1071-1086. doi: 10.3233/XST-180472. J Xray Sci Technol. 2019. PMID: 31476194 Review.
-
The Role for Radiation Therapy in the Management of Sarcoma.Surg Clin North Am. 2016 Oct;96(5):1127-39. doi: 10.1016/j.suc.2016.05.003. Surg Clin North Am. 2016. PMID: 27542646 Review.
Cited by
-
Advances and potential of optical surface imaging in radiotherapy.Phys Med Biol. 2022 Aug 9;67(16):10.1088/1361-6560/ac838f. doi: 10.1088/1361-6560/ac838f. Phys Med Biol. 2022. PMID: 35868290 Free PMC article. Review.
-
Incorporating breath holding and image guidance in the adjuvant gastric cancer radiotherapy: a dosimetric study.Radiat Oncol. 2012 Jun 20;7:98. doi: 10.1186/1748-717X-7-98. Radiat Oncol. 2012. PMID: 22716276 Free PMC article. Clinical Trial.
-
Detecting intra-fraction motion in patients undergoing radiation treatment using a low-cost wireless accelerometer.Sensors (Basel). 2009;9(9):6715-29. doi: 10.3390/s90906715. Epub 2009 Aug 27. Sensors (Basel). 2009. PMID: 22423196 Free PMC article.
-
Utility of a skin marker-less setup procedure using surface-guided imaging: a comparison with the traditional laser-based setup in extremity irradiation.Radiol Phys Technol. 2024 Jun;17(2):569-577. doi: 10.1007/s12194-024-00806-w. Epub 2024 Apr 26. Radiol Phys Technol. 2024. PMID: 38668937
-
A study on prostate movement and dosimetric variation because of bladder and rectum volumes changes during the course of image-guided radiotherapy in prostate cancer.Prostate Int. 2020 Jun;8(2):91-97. doi: 10.1016/j.prnil.2019.12.003. Epub 2020 Feb 27. Prostate Int. 2020. PMID: 32647646 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical