Intraindividual in vivo comparison of gadolinium contrast agents for pharmacokinetic analysis using dynamic contrast enhanced magnetic resonance imaging
- PMID: 20351653
- DOI: 10.1097/RLI.0b013e3181d54507
Intraindividual in vivo comparison of gadolinium contrast agents for pharmacokinetic analysis using dynamic contrast enhanced magnetic resonance imaging
Abstract
Purpose: To compare the intraindividual differences of dynamic signal characteristics for 3 gadolinium chelates (gadopentetate dimeglumine [Gd-DTPA], gadodiamide [Gd-DTPA-BMA], and gadobenate dimeglumine [Gd-BOPTA]) using dynamic contrast enhanced magnetic resonance (MR) imaging (DCE-MRI) with a preclinical beagle model at 7 Tesla.
Method and materials: Seven beagles were scanned 3 times each with a 7-day interval between the scans on a 7T whole body MRI system (Achieva, Philips) using a T/R head coil. Three different Gd contrast agents including Gd-DTPA, Gd-DTPABMA, and Gd-BOPTA were injected in a randomized order with a power injector (Spectris, MedRad, Indianola, PA) using dose of 0.1 mmol/kg body weight and flow rate of 0.06 mL/s. During image acquisition and data analysis, the identity of the specific contrast agent used for each examination was blinded. A 3D RF-spoiled fast field echo sequence was used for dynamic scans with in-plane spatial resolution 0.47 x 0.47 mm(2), temporal resolution of 9.5 seconds, and a total of 60 time points. Regions of interest were drawn within the carotid arteries and muscle tissue to determine semiquantitative parameters including maximum enhancement ratio, area under the signal enhancement curve over 90 seconds after contrast injection (AUC_90), time to maximum signal enhancement (T(max)), and washout_score. Additionally, quantitative pharmacokinetic parameters were measured in muscle tissues by applying 3 separate 2-compartment models; (1) artery input function (AIF) based Tofts model, (2) Brix model without AIF, and (3) AIF decomposed refined Brix model.
Results: Gd-BOPTA produced higher signal to noise ratio on postcontrast T1- weighted images than the other 2 Gd based contrast agents at 7T. Quantitatively, Gd-BOPTA provided a significantly higher maximum enhancement ratio (P < 0.01), AUC_90 (P < 0.01) and washout_score (P < 0.01) in beagle musculature and cranial vasculature compared with both Gd-DTPA and Gd-DTPA-BMA. Among all the quantitative pharmacokinetic parameters, only the exchange rate constants (kep) calculated from these 3 models did not show a significant difference among the various contrast agents.
Conclusions: Gd chelate containing MR contrast agents can be used at 7T for DCEMRI. Gd-BOPTA demonstrates stronger signal enhancement than standard Gd chelates, in concordance with the results of studies at lower fields. The observed enhancement characteristics for the 3 contrast agents demonstrate that the pharmacokinetic parameter kep is more robust in various models using DCE-MRI than the other pharmacokinetic parameters. This information is important relative to multisite clinical trials and long-term clinical studies that often use several different contrast agents and different models.
Similar articles
-
The efficacy of gadobenate dimeglumine (Gd-BOPTA) at 3 Tesla in brain magnetic resonance imaging: comparison to 1.5 Tesla and a standard gadolinium chelate using a rat brain tumor model.Invest Radiol. 2006 Mar;41(3):244-8. doi: 10.1097/01.rli.0000191332.24773.e7. Invest Radiol. 2006. PMID: 16481906
-
Contrast-enhanced MR angiography of the run-off vasculature: intraindividual comparison of gadobenate dimeglumine with gadopentetate dimeglumine.J Magn Reson Imaging. 2003 Jun;17(6):694-702. doi: 10.1002/jmri.10313. J Magn Reson Imaging. 2003. PMID: 12766899 Clinical Trial.
-
Reproducibility of the aortic input function (AIF) derived from dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) of the kidneys in a volunteer study.Eur J Radiol. 2009 Sep;71(3):576-81. doi: 10.1016/j.ejrad.2008.09.025. Epub 2008 Nov 11. Eur J Radiol. 2009. PMID: 19004588
-
Liver. III: Gadolinium-based hepatobiliary contrast agents (Gd-EOB-DTPA and Gd-BOPTA/Dimeg).Magn Reson Imaging Clin N Am. 1996 Feb;4(1):61-72. Magn Reson Imaging Clin N Am. 1996. PMID: 8673717 Review.
-
Gadobenate dimeglumine 0.5 M solution for injection (MultiHance) as contrast agent for magnetic resonance imaging of the liver: mechanistic studies in animals.J Comput Assist Tomogr. 1999 Nov;23 Suppl 1:S169-79. doi: 10.1097/00004728-199911001-00022. J Comput Assist Tomogr. 1999. PMID: 10608413 Review.
Cited by
-
Brain tumours at 7T MRI compared to 3T--contrast effect after half and full standard contrast agent dose: initial results.Eur Radiol. 2015 Jan;25(1):106-12. doi: 10.1007/s00330-014-3351-2. Epub 2014 Sep 7. Eur Radiol. 2015. PMID: 25194707 Free PMC article.
-
Assessment of DCE-MRI parameters for brain tumors through implementation of physiologically-based pharmacokinetic model approaches for Gd-DOTA.J Pharmacokinet Pharmacodyn. 2016 Oct;43(5):529-47. doi: 10.1007/s10928-016-9493-x. Epub 2016 Sep 19. J Pharmacokinet Pharmacodyn. 2016. PMID: 27647272
-
High-grade soft-tissue sarcoma: optimizing injection improves MRI evaluation of tumor response.Eur Radiol. 2019 Feb;29(2):545-555. doi: 10.1007/s00330-018-5635-4. Epub 2018 Jul 23. Eur Radiol. 2019. PMID: 30039222
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical