A Bayesian measurement error approach to QT interval correction and prolongation
- PMID: 20358434
- DOI: 10.1080/10543400903581960
A Bayesian measurement error approach to QT interval correction and prolongation
Abstract
Assessment of QT interval prolongation is an integral part of clinical studies in drug development because a prolonged QT interval can cause sudden cardiac death. Traditionally a linear or non-linear regression method is applied to estimate subject- or group-specific heart rate corrected QT intervals (QTc) on which comparisons are based among treatment groups. These regression models rely on a fundamental assumption that the predictor variable (RR interval) is measured without error. However, the fact is that both QT and RR intervals measured in electrocardiogram (ECG) are subject to not only measurement error, but also fluctuation that is caused by physiological and biological factors. Hence the assumption in the regression models is most likely violated. In this paper we propose a Bayesian hierarchical measurement error model to evaluate QTc interval and prolongation. The proposed approach is illustrated using a real data set. Simulation studies show that our proposed Bayesian measurement error approach outperforms the current most commonly used frequentist methods.
Similar articles
-
Statistical characterization of QT prolongation.J Biopharm Stat. 2010 May;20(3):543-62. doi: 10.1080/10543400903581978. J Biopharm Stat. 2010. PMID: 20358435
-
A nonparametric approach to QT interval correction for heart rate.J Biopharm Stat. 2010 May;20(3):508-22. doi: 10.1080/10543400903581952. J Biopharm Stat. 2010. PMID: 20358433
-
QT analysis: a complex answer to a 'simple' problem.Stat Med. 2004 Sep 15;23(17):2625-43. doi: 10.1002/sim.1863. Stat Med. 2004. PMID: 15316947
-
Multiple comparisons of repeated measured response: issues of assessment of prolongation of QT interval in thorough QT trials.J Biopharm Stat. 2010 May;20(3):604-14. doi: 10.1080/10543400903582034. J Biopharm Stat. 2010. PMID: 20358439 Review.
-
Assessing QT prolongation and electrocardiography restitution using a beat-to-beat method.Cardiol J. 2010;17(3):230-43. Cardiol J. 2010. PMID: 20535712 Review.
Cited by
-
Nomenclature, categorization and usage of formulae to adjust QT interval for heart rate.World J Cardiol. 2015 Jun 26;7(6):315-25. doi: 10.4330/wjc.v7.i6.315. World J Cardiol. 2015. PMID: 26131336 Free PMC article. Review.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical