Abstract
Interest in atmospheric dry deposition results mostly from concerns about the effects of the deposited trace elements entering waterbody, soil and vegetation as well as their subsequent health effects. A microwave assisted digestion method followed by inductively coupled plasma mass spectrometric (MAD-ICP/MS) analysis was developed to determine the concentrations of a large number of trace metals in atmospheric dry deposition samples with a heavy matrix of polyurethane foam (PUF). A combination of HNO3-H2O2-HF was used for digestion. The experimental protocol for the microwave assisted digestion was established using two different SRMs (GBW 07401, Soil and GBW 08401, Coal fly ash). Subsequently, blanks and limits of detection for total trace metal concentrations were determined for PUF filter which was used for dry deposition sampling. Finally, the optimized digestion method was applied to real world atmospheric dry deposition samples collected at 10 sites in Jingjinji area in winter from Dec. 2007 to Feb. 2008. The results showed that the area-averaged total mass fluxes ranged between 85 and 912 mg x (m2 x d)(-1), and fluxes of most elements were highest at Baoding and lowest at Xinglong. In addition, the elemental fluxes in urban areas of Beijing, Tianjin and Tangshan were measured to be higher than that in suburb and rural sites. The average fluxes of crust elements (A1, Fe, Mn, K, Na, Ca and Mg) were one to three orders of magnitude higher than anthropogenic elements (Cu, Pb, Cr, Ni, V, Zn and Ba), varying from 151 to 16034 microg x (m2 x d)(-1) versus 14 to 243 microg x (m2 x d)(-1). Zinc was the most abundant heavy metal and calcium the highest of the crust elements while the elements Mo, Co, Cd, As and Be deposited less or even could not be detected. The anthropogenic and crustal contributions were estimated by employing enrichment factors (EF) calculated relative to the average crustal composition. The EF values of all elements except Pb and Zn were below 10, suggesting that local soil and/or dust generally dominate in the dry deposition flux.
Similar articles
-
Microwave assisted digestion of atmospheric aerosol samples followed by inductively coupled plasma mass spectrometry determination of trace elements.Fresenius J Anal Chem. 2001 Jan 1;369(1):63-70. doi: 10.1007/s002160000575. Fresenius J Anal Chem. 2001. PMID: 11210233
-
Atmospheric dry deposition fluxes of trace elements measured in Bursa, Turkey.Environ Pollut. 2005 Dec;138(3):462-72. doi: 10.1016/j.envpol.2005.04.012. Environ Pollut. 2005. PMID: 15955602
-
Simultaneous determination of suspended particulate trace metals (Co, Ni, Cu, Zn, Cd and Pb) in seawater with small volume filtration assisted by microwave digestion and flow injection inductively coupled plasma mass spectrometer.Anal Chim Acta. 2007 Jun 26;594(1):52-60. doi: 10.1016/j.aca.2007.04.057. Epub 2007 May 3. Anal Chim Acta. 2007. PMID: 17560385
-
Validation and quality control of an ICP-MS method for the quantification and discrimination of trace metals and application in paper analysis: an overview.Crit Rev Anal Chem. 2014;44(4):311-27. doi: 10.1080/10408347.2013.863141. Crit Rev Anal Chem. 2014. PMID: 25391719 Review.
-
Trace elements in street and house dusts: sources and speciation.Sci Total Environ. 1991 Mar;100 Spec No:125-50. doi: 10.1016/0048-9697(91)90376-p. Sci Total Environ. 1991. PMID: 2063179 Review.