Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1991 May;66(5):431-5.

Dermatophagoides farinae allergen levels from two different sources within the same home: evaluation of two different collection techniques

Affiliations
  • PMID: 2035907
Comparative Study

Dermatophagoides farinae allergen levels from two different sources within the same home: evaluation of two different collection techniques

J T Twiggs et al. Ann Allergy. 1991 May.

Abstract

The allergens produced by the dust mites of the Dermatophagoides genus are now recognized as one of the major allergens in house dust. Quantification of those allergens helps to evaluate the effectiveness of avoidance measures and specific treatments aimed at the reduction of the mites and their allergens. The present study was undertaken to compare the level of D. farinae allergen collected by a standard vacuum cleaner with a disposable bag and the level of allergen collected by a hand-held vacuum equipped with a special filter. Samples were obtained from the main living area of 18 homes of patients allergic to D. farinae. Using a hand-held vacuum especially equipped with a removable micropore filter, a 2-m2 area of carpet was vacuumed for two minutes and an identical sample was collected from the major upholstered piece of furniture in the room. A third sample was obtained with an upright vacuum fitted with a clean disposable bag. The dust collected was extracted in phosphate buffered saline and resultant extracts were assayed for D. farinae allergen content by microtiter plate RAST inhibition assay. Results from these assays showed a large interhome variability regardless of sampling technique, but intrahome sampling showed remarkable consistency. A linear regression analysis demonstrated all of the comparisons correlated at a probability level of P less than .05. We conclude that dust mite allergen levels collected in a disposable bag vacuum cleaner are reliable indicators of the level of house dust mites present in the homes of patients.

PubMed Disclaimer

Similar articles

Cited by

Publication types