Management of exposure to waste anesthetic gases
- PMID: 20362214
- DOI: 10.1016/j.aorn.2009.10.022
Management of exposure to waste anesthetic gases
Abstract
Anesthetic agents were developed in the 1700s, and nitrous oxide was first used in 1884. Research on the effects of waste anesthetic gas exposure started appearing in the literature in 1967. Short-term exposure causes lethargy and fatigue, and long-term exposure may be linked to spontaneous abortion, congenital abnormalities, infertility, premature births, cancer, and renal and hepatic disease. Today, perioperative staff members are exposed to trace amounts of waste anesthetic gas, and although this exposure cannot be eliminated, it can be controlled. Health care facilities are required to develop, implement, measure, and control practices to reduce anesthetic gas exposure to the lowest practical level. Exposure levels must be measured every six months and maintained at less than 25 parts per million for nitrous oxide and 2 parts per million for halogenated agents to be compliant with Occupational Safety and Health Administration standards.
Copyright 2010 AORN, Inc. Published by Elsevier Inc. All rights reserved.
Comment in
-
Maintenance and repair of anesthesia machines.AORN J. 2011 Feb;93(2):195; author reply 195-6. doi: 10.1016/j.aorn.2010.12.008. AORN J. 2011. PMID: 21281756 No abstract available.
Similar articles
-
[A study of waste anesthetic gases monitoring and working environmental controls in hospital operating rooms].Sangyo Eiseigaku Zasshi. 1997 Jan;39(1):38-45. Sangyo Eiseigaku Zasshi. 1997. PMID: 9138776 Japanese.
-
N2O. How safe is it?CDS Rev. 1996 Oct;89(9):12-22. CDS Rev. 1996. PMID: 9528426 No abstract available.
-
Nitrous oxide analgesia. What is a safe level of exposure for the dental staff?Dent Today. 2002 Apr;21(4):104-9. Dent Today. 2002. PMID: 11957224 Review. No abstract available.
-
[Occupational exposure of the anesthesiologist to nitrous oxide and halothane. Control measures].Rev Esp Anestesiol Reanim. 1989 Sep-Oct;36(5):267-75. Rev Esp Anestesiol Reanim. 1989. PMID: 2687969 Review. Spanish.
-
Scavenging anesthetic gas from a membrane oxygenator during cardiopulmonary bypass.J Extra Corpor Technol. 1996 Jun;28(2):88-90. J Extra Corpor Technol. 1996. PMID: 10160449
Cited by
-
Chemical risk in hospital settings: Overview on monitoring strategies and international regulatory aspects.J Public Health Res. 2021 Mar 24;10(1):1993. doi: 10.4081/jphr.2021.1993. J Public Health Res. 2021. PMID: 33849259 Free PMC article.
-
Field application of SPME as a novel tool for occupational exposure assessment with inhalational anesthetics.Environ Monit Assess. 2012 Nov;184(11):6483-90. doi: 10.1007/s10661-011-2434-7. Epub 2011 Nov 18. Environ Monit Assess. 2012. PMID: 22089627
-
Waste anesthetic gas exposure and strategies for solution.J Anesth. 2018 Apr;32(2):269-282. doi: 10.1007/s00540-018-2448-1. Epub 2018 Feb 5. J Anesth. 2018. PMID: 29404778 Review.
-
Waste anesthetic gases have a significant association with deoxyribonucleic acid (DNA) damage: A systematic review and meta-analysis of 2,732 participants.Heliyon. 2023 Sep 9;9(9):e19988. doi: 10.1016/j.heliyon.2023.e19988. eCollection 2023 Sep. Heliyon. 2023. PMID: 37810053 Free PMC article.
-
Risk Management Status of Waste Anesthetic Gases Using ECRI Institute Standards.Iran J Public Health. 2012;41(11):85-91. Epub 2012 Nov 1. Iran J Public Health. 2012. PMID: 23304681 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical