Measurement of tissue perfusion by dynamic computed tomography
- PMID: 2036562
- DOI: 10.1259/0007-1285-64-761-409
Measurement of tissue perfusion by dynamic computed tomography
Abstract
A method for quantifying tissue perfusion by dynamic computed tomography (CT) is described. By applying a nuclear medicine data processing technique to time-density data from a single-location dynamic CT sequence, tissue perfusion can be determined from the maximum gradient of the tissue time-density curve divided by the peak enhancement of the aorta. Using this method, splenic perfusion was measured at 1.2 ml min-1 ml-1, normal renal cortical perfusion at 2.5 ml min-1 ml-1 and normal renal medullary perfusion at 1.1 ml min-1 ml-1. Changes in cortical and medullary perfusion in renal failure and hypertension were demonstrated. The ability of dynamic CT to provide quantitative functional information is not well recognized and is potentially of value when studying structures, such as the renal cortex and medulla, that cannot be anatomically resolved by standard functional imaging techniques.
Comment in
-
Measurement of tissue perfusion by dynamic computed tomography.Br J Radiol. 1992 Jun;65(774):554-5. doi: 10.1259/0007-1285-65-774-554-b. Br J Radiol. 1992. PMID: 1628194 No abstract available.
Similar articles
-
Functional imaging of changes in human intrarenal perfusion using quantitative dynamic computed tomography.Invest Radiol. 1994 Oct;29(10):911-4. doi: 10.1097/00004424-199410000-00008. Invest Radiol. 1994. PMID: 7852043
-
Perfusion computed tomography could be a new tool for single-session imaging of ureteric obstructive pathology: an experimental study in rats.J Pediatr Surg. 2009 Oct;44(10):1977-83. doi: 10.1016/j.jpedsurg.2009.01.072. J Pediatr Surg. 2009. PMID: 19853758
-
Dual energy CT monitoring of the renal corticomedullary sodium gradient in swine.Eur J Radiol. 2012 Mar;81(3):423-9. doi: 10.1016/j.ejrad.2010.12.047. Epub 2011 Jan 14. Eur J Radiol. 2012. PMID: 21237601 Free PMC article.
-
MR imaging of renal function.Magn Reson Imaging Clin N Am. 1997 Feb;5(1):107-26. Magn Reson Imaging Clin N Am. 1997. PMID: 8995128 Review.
-
[Contribution of X-ray computed tomography in the evaluation of kidney performance].Nephrol Ther. 2012 Jul;8(4):206-11. doi: 10.1016/j.nephro.2011.07.413. Epub 2011 Oct 22. Nephrol Ther. 2012. PMID: 22019734 Review. French.
Cited by
-
Repeatability of renal arterial spin labelling MRI in healthy subjects.MAGMA. 2012 Apr;25(2):145-53. doi: 10.1007/s10334-011-0300-9. Epub 2012 Jan 13. MAGMA. 2012. PMID: 22246289
-
320-row CT renal perfusion imaging in patients with aortic dissection: A preliminary study.PLoS One. 2017 Feb 9;12(2):e0171235. doi: 10.1371/journal.pone.0171235. eCollection 2017. PLoS One. 2017. PMID: 28182709 Free PMC article. Clinical Trial.
-
Metabolic-flow relationships in primary breast cancer: feasibility of combined PET/dynamic contrast-enhanced CT.Eur J Nucl Med Mol Imaging. 2009 Mar;36(3):416-21. doi: 10.1007/s00259-008-0948-1. Epub 2008 Sep 26. Eur J Nucl Med Mol Imaging. 2009. PMID: 18818917
-
Super-resolution Ultrasound Imaging.Ultrasound Med Biol. 2020 Apr;46(4):865-891. doi: 10.1016/j.ultrasmedbio.2019.11.013. Epub 2020 Jan 21. Ultrasound Med Biol. 2020. PMID: 31973952 Free PMC article. Review.
-
Perfusion CT to assess angiogenesis in colon cancer: technical limitations and practical challenges.Br J Radiol. 2012 Oct;85(1018):e814-25. doi: 10.1259/bjr/19855447. Epub 2012 Apr 18. Br J Radiol. 2012. PMID: 22514101 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Miscellaneous