Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2010 Apr;5(4):380-4.
doi: 10.3171/2009.10.PEDS09296.

Equivalence of fusion rates after rigid internal fixation of the occiput to C-2 with or without C-1 instrumentation

Affiliations
Comparative Study

Equivalence of fusion rates after rigid internal fixation of the occiput to C-2 with or without C-1 instrumentation

Todd C Hankinson et al. J Neurosurg Pediatr. 2010 Apr.

Abstract

Object: The object of this study was to assess a multiinstitutional experience with pediatric occipitocervical constructs to determine whether a difference exists between the fusion and complication rates of constructs with or without direct C-1 instrumentation.

Methods: Seventy-seven cases of occiput-C2 instrumentation and fusion, performed at 9 children's hospitals, were retrospectively analyzed. Entry criteria included atlantooccipital instability with or without atlantoaxial instability. Any case involving subaxial instability was excluded. Constructs were divided into 3 groups based on the characteristics of the anchoring spinal instrumentation: Group 1, C-2 instrumentation; Group 2, C-1 and C-2 instrumentation without transarticular screw (TAS) placement; and Group 3, any TAS placement. Groups were compared based on rates of fusion and perioperative complications.

Results: Group 1 consisted of 16 patients (20.8%) and had a 100% rate of radiographically demonstrated fusion. Group 2 included 22 patients (28.6%), and a 100% fusion rate was achieved, although 2 cases were lost to follow-up before documented fusion. Group 3 included 39 patients (50.6%) and demonstrated a 100% radiographic fusion rate. Complication rates were 12.5, 13.7, and 5.1%, respectively. There were 3 vertebral artery injuries, 1 (4.5%) in Group 2 and 2 (5.1%) in Group 3.

Conclusions: High fusion rates and low complication rates were achieved with each configuration examined. There was no difference in fusion rates between the group without (Group 1) and those with (Groups 2 and 3) C-1 instrumentation. These findings indicated that in the pediatric population, excellent occipitocervical fusion rates can be accomplished without directly instrumenting C-1.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources