Electronic compliance monitoring of topical treatment after ophthalmic surgery

Affiliations

Electronic compliance monitoring of topical treatment after ophthalmic surgery

Manuel Marcel Hermann et al. Int Ophthalmol. 2010 Aug.

Abstract

The success of many medical treatments is built on compliance. Electronic monitoring is the most accurate tool to quantify compliance by measuring adherence. In order to assess the efficiency of a recently introduced miniature monitoring device for eye drop application, we evaluated adherence in ophthalmic patients undergoing post-operative short-term topical treatment. This pilot study enrolled 30 outpatients (mean age 61.8 +/- 18.5 years) after cataract (n = 24) and glaucoma filtration surgery (n = 6) applying fixed-combination eye drops containing prednisolone and gentamicin five times daily for 2 weeks. Patients received eye drops in conventional bottles each equipped with a miniature monitoring device recording events of application. Two patients failed to bring back the monitoring device; therefore data collected from only 28 patients could be examined. Data showed highly variable results with a mean dose compliance of 50.2%. Dose compliance was below 25% in approximately one out of five patients. Four cataract patients, but no glaucoma patient, discontinued therapy prematurely. The observed mean dosage interval was calculated for each patient and ranged 4.6-19.7 h. Thirty percent of analysed dosage intervals exceeded 12.0 h. Different patterns of compliance behaviour-like early non-persistence, drug holiday and low treatment frequency could be identified and illustrated using electronic data. Age or gender did not significantly influence compliance rates. Our pilot study demonstrates successful electronic compliance monitoring using a technology capable of continuous data recording over weeks of treatment. The low compliance rate for a relevant part of the patients demonstrates the necessity to study and improve compliance in ophthalmology. In future, new application methods and electronic application devices may improve treatment response in eye care.

PubMed Disclaimer

References

    1. Am J Ophthalmol. 2006 Jan;141(1 Suppl):S28-33 - PubMed
    1. Am J Ophthalmol. 2007 Oct;144(4):533-40 - PubMed
    1. Ophthalmology. 2005 Jun;112(6):953-61 - PubMed
    1. Curr Opin Ophthalmol. 2006 Apr;17(2):190-5 - PubMed
    1. Invest Ophthalmol Vis Sci. 2007 Nov;48(11):5052-7 - PubMed

MeSH terms

Substances

LinkOut - more resources