Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 1991 Apr;31(4):342-7.
doi: 10.1002/j.1552-4604.1991.tb03715.x.

AICA-riboside: safety, tolerance, and pharmacokinetics of a novel adenosine-regulating agent

Affiliations
Clinical Trial

AICA-riboside: safety, tolerance, and pharmacokinetics of a novel adenosine-regulating agent

R Dixon et al. J Clin Pharmacol. 1991 Apr.

Abstract

AICA-riboside (5-amino-4-imidazole carboxamide ribonucleoside) is a novel adenosine-regulating agent that is currently being investigated for the treatment of ischemic heart disease. In a placebo-controlled, double-blind study in healthy men, we evaluated the safety and kinetics of the drug after oral and IV administration of 10, 25, 50, and 100 mg/kg doses. At each dose level, four subjects received active drug and two subjects received placebo with a 1-week wash-out period between the IV and oral doses. The drug was well tolerated at all dose levels with only mild and transient side effects reported in some instances by the subjects who received placebo and those patients who received the drug. The post-infusion plasma concentrations of AICA-riboside declined rapidly in a biphasic fashion, and the terminal elimination phase had a harmonic mean t1/2 beta of 1.4 hours. Total plasma clearance (CL), mean residence time (MRTIV), and volume of distribution at steady-state (VSS) were 2.5 L/hr/kg, 0.7 hr, and 1.6 L/kg, respectively. The drug was not protein bound, and there was rapid uptake and phosphorylation in RBCs to its 5'-monophosphate nucleotide. Renal clearance (CLR) was 0.2 L/hr/kg with only 8% of the IV dose excreted in the urine as intact AICA-riboside. Although there was a trend towards a decrease in CL with increasing dose, there were no significant differences (P greater than .05) in the mean estimates of t1/2 beta, CL, CLR, MRTIV and VSS associated with dose. The drug was poorly bioavailable (less than 5%) when administered orally in solution.

PubMed Disclaimer

MeSH terms

LinkOut - more resources