Which procedure better restores intact hip range of motion: total hip arthroplasty or resurfacing? A combined cadaveric and computer simulation study
- PMID: 20378308
- DOI: 10.1016/j.arth.2010.02.001
Which procedure better restores intact hip range of motion: total hip arthroplasty or resurfacing? A combined cadaveric and computer simulation study
Abstract
Previous comparisons of hip range of motion (ROM) after THA and surface replacement arthroplasty (SRA) are inconclusive due to the lack of soft tissue considerations and dissimilar control groups. The normal ROMs of 8 intact cadaveric hips were determined by placing specimens in 6 discrete, predefined positions of rotation at a standard torque. In each position, the limiting factor of ROM, either bony impingement or soft tissue restriction, could be determined. Total hip arthroplasty and SRA components were virtually implanted, and ROM until impingement was determined. With a THA, the ROM was comparable to that of the intact hip. With an SRA, flexion (111° ± 13°) was less than for the intact hip (131° ± 6°). Surface replacement arthroplasty, but not THA, significantly decreases the ROM compared to intact hips.
Copyright © 2011 Elsevier Inc. All rights reserved.
Similar articles
-
Anatomic hip range of motion after implantation during total hip arthroplasty as measured by a navigation system.J Arthroplasty. 2007 Oct;22(7):946-52. doi: 10.1016/j.arth.2007.02.004. J Arthroplasty. 2007. PMID: 17920464
-
The safe-zones for combined cup and neck anteversions that fulfill the essential range of motion and their optimum combination in total hip replacements.J Biomech. 2006;39(7):1315-23. doi: 10.1016/j.jbiomech.2005.03.008. J Biomech. 2006. PMID: 15894324
-
[Femur first in hip arthroplasty--the concept of combined anteversion].Z Orthop Unfall. 2010 Mar;148(2):185-90. doi: 10.1055/s-0029-1240969. Epub 2010 Apr 7. Z Orthop Unfall. 2010. PMID: 20376760 German.
-
Why total hip resurfacing.J Arthroplasty. 2007 Oct;22(7 Suppl 3):57-60. doi: 10.1016/j.arth.2007.05.050. J Arthroplasty. 2007. PMID: 17919595 Review.
-
Review: biomechanical issues in total hip replacement.Surg Technol Int. 2012 Dec;22:222-8. Surg Technol Int. 2012. PMID: 23023572 Review.
Cited by
-
Calibration procedure and biomechanical validation of an universal six degree-of-freedom robotic system for hip joint testing.J Orthop Surg Res. 2023 Mar 3;18(1):164. doi: 10.1186/s13018-023-03601-2. J Orthop Surg Res. 2023. PMID: 36869379 Free PMC article.
-
In vitro hip testing in the International Society of Biomechanics coordinate system.J Biomech. 2016 Dec 8;49(16):4154-4158. doi: 10.1016/j.jbiomech.2016.10.036. Epub 2016 Oct 29. J Biomech. 2016. PMID: 27836503 Free PMC article.
-
Low femoral antetorsion and total hip arthroplasty: a risk factor.Int Orthop. 2015 Jan;39(1):7-12. doi: 10.1007/s00264-014-2452-5. Epub 2014 Aug 3. Int Orthop. 2015. PMID: 25086820
-
Bony impingement depends on the bone morphology of the hip after total hip arthroplasty.Int Orthop. 2013 Oct;37(10):1897-903. doi: 10.1007/s00264-013-1979-1. Epub 2013 Jul 17. Int Orthop. 2013. PMID: 23860789 Free PMC article.
-
Does acetabular retroversion affect range of motion after total hip arthroplasty?Clin Orthop Relat Res. 2011 Jan;469(1):218-24. doi: 10.1007/s11999-010-1482-6. Epub 2010 Jul 28. Clin Orthop Relat Res. 2011. PMID: 20665139 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical