[Evaluation of heart impact in the 100 m extreme intensity sport using near-infrared non-invasive muscle oxygen detecting device and sports heart rate detection technology]
- PMID: 20384120
[Evaluation of heart impact in the 100 m extreme intensity sport using near-infrared non-invasive muscle oxygen detecting device and sports heart rate detection technology]
Abstract
Using continuous two wavelength near-infrared technology to detect the variation in the consistency of oxygen hemoglobin in the muscle and the sports heart rate wireless real time collection technology, we devised the real time muscle tissue oxygenation and instantaneous heart rate experiment scheme and implemented it for the process of the 100 m run with two parameters given simultaneously. The experiment shows that the concentration of the oxygen hemoglobin in the muscle tissue continues decreasing after the end of the 100 m run, and the time interval between the moment when the concentration of the oxygen hemoglobin attains the minimum value and the moment when the athletes finish the 100 m run is (6.65 +/- 1.10) sec; while the heart rate continues increasing after the end of the 100 m run, and the time interval between the moment when the heart rate attains the maximum value and the moment when the athletes finish the 100 m run is (8.00 +/- 1.57) sec. The results show that the two wavelength near-infrared tissue oxygenation detection technology and the sports heart rate real time collection equipment can accurately measure the sports tissue oxygenation and the heart rate in the extreme intensity sport, and reveal the process of muscle oxygen transportation and consumption and its dynamic character with the heart rate in the extreme intensity sport.
Similar articles
-
The use of portable NIRS to measure muscle oxygenation and haemodynamics during a repeated sprint running test.Adv Exp Med Biol. 2013;789:185-191. doi: 10.1007/978-1-4614-7411-1_26. Adv Exp Med Biol. 2013. PMID: 23852494
-
Localized irregularities in hemoglobin flow and oxygenation in calf muscle in patients with peripheral vascular disease detected with near-infrared spectrophotometry.J Vasc Surg. 2003 May;37(5):1017-26. doi: 10.1067/mva.2003.214. J Vasc Surg. 2003. PMID: 12756348
-
[To the question of the heart rate fluctuations during submaximal workload].Fiziol Zh (1994). 2012;58(3):60-71. Fiziol Zh (1994). 2012. PMID: 22946314 Ukrainian.
-
The use of muscle near-infrared spectroscopy in sport, health and medical sciences: recent developments.Philos Trans A Math Phys Eng Sci. 2011 Nov 28;369(1955):4591-604. doi: 10.1098/rsta.2011.0298. Philos Trans A Math Phys Eng Sci. 2011. PMID: 22006908 Review.
-
Monitoring tissue blood flow and oxygenation: a brief review of emerging techniques.Crit Care Nurs Clin North Am. 2014 Sep;26(3):345-56. doi: 10.1016/j.ccell.2014.04.003. Crit Care Nurs Clin North Am. 2014. PMID: 25169688 Review.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources