Electrochemistry in diabetes management
- PMID: 20384299
- DOI: 10.1021/ar9002015
Electrochemistry in diabetes management
Abstract
Diabetes devastates lives and burdens society. Hypoglycemic (low glucose) episodes cause blackouts, and severe ones are life-threatening. Periods of hyperglycemia (high glucose) cause circulatory disease, stroke, amputations, blindness, kidney failure and nerve degeneration. In this Account, we describe the founding of TheraSense, now a major part of Abbott Diabetes Care, and the development of two products that have improved the lives of people with diabetes. The first, a virtually painless microcoulometer (300 nL volume), the FreeStyle blood glucose monitoring system, was approved by the FDA and became available in 2000. In 2009, this system was used in more than one billion blood assays. The second, the enzyme-wiring based, subcutaneously-implanted FreeStyle Navigator continuous glucose monitoring system, was approved by the FDA and became available in the United States in 2008. The strips of the FreeStyle blood glucose monitoring system comprise a printed parallel plate coulometer, with a 50 microm gap between two facing printed electrodes, a carbon electrode and a Ag/AgCl electrode. The volume of blood between the facing plates is accurately controlled. The glucose is electrooxidized through catalysis by a glucose dehydrogenase (GDH) and an Os(2+/3+) redox mediator, which is reduced by the glucose-reduced enzyme and is electrooxidized on the carbon electrode. Initially the system used pyrroloquinoline quinone (PQQ)-dependent GDH but now uses flavin adenine dinucleotide (FAD)-dependent GDH. Because the facing electrodes are separated by such a small distance, shuttling of electrons by the redox couple could interfere with the coulometric assay. However, the Os(2+/3+) redox mediator is selected to have a substantially negative formal potential, between 0.0 and -0.2 V, versus that of the facing Ag/AgCl electrode. This makes the flow of a shuttling current between the two electrodes virtually impossible because the oxidized Os(3+) complex cannot be appreciably reduced at the more positively poised Ag/AgCl electrode. The FreeStyle Navigator continuous glucose monitoring system uses a subcutaneously implanted miniature plastic sensor connected to a transmitter to measure glycemia amperometrically and sends the information to a PDA-like device every minute. The sensor consists of a narrow (0.6 mm wide) plastic substrate on which carbon-working, Ag/AgCl reference, and carbon counter electrodes are printed in a stacked geometry. The active wired enzyme sensing layer covers only about 0.1 mm(2) of the working electrode and is overlaid by a flux-limiting membrane. It resides at about 5 mm depth in the subcutaneous adipose tissue and monitors glucose concentrations over the range 20-500 mg/dL. Its core component, a miniature, disposable, amperometric glucose sensor, has an electrooxidation catalyst made from a crosslinked adduct of glucose oxidase (GOx) and a GOx wiring redox hydrogel containing a polymer-bound Os(2+/3+) complex. Because of the selectivity of the catalyst for glucose, very little current flows in the absence of glucose. That feature, either alone or in combination with other features of the sensor, facilitates the one-point calibration of the system. The sensor is implanted subcutaneously and replaced by the patient after 5 days use with minimal pain. The wearer does not feel its presence under the skin.
Similar articles
-
On-line removal of redox-active interferents by a porous electrode before amperometric blood glucose determination.Anal Chim Acta. 2012 Mar 16;719:52-6. doi: 10.1016/j.aca.2012.01.008. Epub 2012 Jan 12. Anal Chim Acta. 2012. PMID: 22340530
-
Design of an Os Complex-Modified Hydrogel with Optimized Redox Potential for Biosensors and Biofuel Cells.Chemistry. 2016 Apr 4;22(15):5319-26. doi: 10.1002/chem.201504591. Epub 2016 Mar 1. Chemistry. 2016. PMID: 26929043
-
Long tethers binding redox centers to polymer backbones enhance electron transport in enzyme "Wiring" hydrogels.J Am Chem Soc. 2003 Apr 23;125(16):4951-7. doi: 10.1021/ja029510e. J Am Chem Soc. 2003. PMID: 12696915
-
Implanted electrochemical glucose sensors for the management of diabetes.Annu Rev Biomed Eng. 1999;1:153-75. doi: 10.1146/annurev.bioeng.1.1.153. Annu Rev Biomed Eng. 1999. PMID: 11701486 Review.
-
From fundamentals to applications of bioelectrocatalysis: bioelectrocatalytic reactions of FAD-dependent glucose dehydrogenase and bilirubin oxidase.Biosci Biotechnol Biochem. 2019 Jan;83(1):39-48. doi: 10.1080/09168451.2018.1527209. Epub 2018 Oct 1. Biosci Biotechnol Biochem. 2019. PMID: 30274547 Review.
Cited by
-
Catalytic Biosensors Operating under Quasi-Equilibrium Conditions for Mitigating the Changes in Substrate Diffusion.Angew Chem Int Ed Engl. 2022 Dec 23;61(52):e202211559. doi: 10.1002/anie.202211559. Epub 2022 Nov 23. Angew Chem Int Ed Engl. 2022. PMID: 36253337 Free PMC article.
-
Effectiveness of Using the FreeStyle Libre® System for Monitoring Blood Glucose during the COVID-19 Pandemic in Diabetic Individuals: Systematic Review.Diagnostics (Basel). 2023 Apr 21;13(8):1499. doi: 10.3390/diagnostics13081499. Diagnostics (Basel). 2023. PMID: 37189600 Free PMC article. Review.
-
A Paper-Based Electrochromic Array for Visualized Electrochemical Sensing.Sensors (Basel). 2017 Jan 31;17(2):276. doi: 10.3390/s17020276. Sensors (Basel). 2017. PMID: 28146120 Free PMC article.
-
Electrochemical biosensors and nanobiosensors.Essays Biochem. 2016 Jun 30;60(1):69-80. doi: 10.1042/EBC20150008. Essays Biochem. 2016. PMID: 27365037 Free PMC article. Review.
-
Metal-organic frameworks for the sorption of acetone and isopropanol in exhaled breath of diabetics prior to quantitation by gas chromatography.Mikrochim Acta. 2019 Jul 31;186(8):588. doi: 10.1007/s00604-019-3713-1. Mikrochim Acta. 2019. PMID: 31367797
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Molecular Biology Databases
Miscellaneous