Quantification of methane in humid air and exhaled breath using selected ion flow tube mass spectrometry
- PMID: 20391601
- DOI: 10.1002/rcm.4513
Quantification of methane in humid air and exhaled breath using selected ion flow tube mass spectrometry
Abstract
In selected ion flow tube mass spectrometry, SIFT-MS, analyses of humid air and breath, it is essential to consider and account for the influence of water vapour in the media, which can be profound for the analysis of some compounds, including H(2)CO, H(2)S and notably CO(2). To date, the analysis of methane has not been considered, since it is known to be unreactive with H(3)O(+) and NO(+), the most important precursor ions for SIFT-MS analyses, and it reacts only slowly with the other available precursor ion, O(2) (+). However, we have now experimentally investigated methane analysis and report that it can be quantified in both air and exhaled breath by exploiting the slow O(2) (+)/CH(4) reaction that produces CH(3)O(2) (+) ions. We show that the ion chemistry is significantly influenced by the presence of water vapour in the sample, which must be quantified if accurate analyses are to be performed. Thus, we have carried out a study of the loss rate of the CH(3)O(2) (+) analytical ion as a function of sample humidity and deduced an appropriate kinetics library entry that provides an accurate analysis of methane in air and breath by SIFT-MS. However, the associated limit of detection is rather high, at 0.2 parts-per-million, ppm. We then measured the methane levels, together with acetone levels, in the exhaled breath of 75 volunteers, all within a period of 3 h, which shows the remarkable sample throughput rate possible with SIFT-MS. The mean methane level in ambient air is seen to be 2 ppm with little spread and that in exhaled breath is 6 ppm, ranging from near-ambient levels to 30 ppm, with no significant variation with age and gender. Methane can now be included in the wide ranging analyses of exhaled breath that are currently being carried out using SIFT-MS.
Copyright (c) 2010 John Wiley & Sons, Ltd.
Similar articles
-
The quantification of carbon dioxide in humid air and exhaled breath by selected ion flow tube mass spectrometry.Rapid Commun Mass Spectrom. 2009 May;23(10):1419-25. doi: 10.1002/rcm.4016. Rapid Commun Mass Spectrom. 2009. PMID: 19347971
-
Influence of water vapour on selected ion flow tube mass spectrometric analyses of trace gases in humid air and breath.Rapid Commun Mass Spectrom. 2000;14(20):1898-906. doi: 10.1002/1097-0231(20001030)14:20<1898::AID-RCM110>3.0.CO;2-G. Rapid Commun Mass Spectrom. 2000. PMID: 11013418
-
Quantification of hydrogen cyanide in humid air by selected ion flow tube mass spectrometry.Rapid Commun Mass Spectrom. 2004;18(16):1869-73. doi: 10.1002/rcm.1566. Rapid Commun Mass Spectrom. 2004. PMID: 15329882
-
Selected ion flow tube mass spectrometry (SIFT-MS) for on-line trace gas analysis.Mass Spectrom Rev. 2005 Sep-Oct;24(5):661-700. doi: 10.1002/mas.20033. Mass Spectrom Rev. 2005. PMID: 15495143 Review.
-
Progress in SIFT-MS: breath analysis and other applications.Mass Spectrom Rev. 2011 Mar-Apr;30(2):236-67. doi: 10.1002/mas.20303. Epub 2010 Jul 20. Mass Spectrom Rev. 2011. PMID: 20648679 Review.
Cited by
-
Effects of dietary nutrients on volatile breath metabolites.J Nutr Sci. 2013 Oct 31;2:e34. doi: 10.1017/jns.2013.26. eCollection 2013. J Nutr Sci. 2013. PMID: 25191584 Free PMC article.
-
Modeling of breath methane concentration profiles during exercise on an ergometer.J Breath Res. 2016 Feb 1;10(1):017105. doi: 10.1088/1752-7155/10/1/017105. J Breath Res. 2016. PMID: 26828421 Free PMC article.
-
Modulated ringdown comb interferometry for sensing of highly complex gases.Nature. 2025 Feb;638(8052):941-948. doi: 10.1038/s41586-024-08534-2. Epub 2025 Feb 19. Nature. 2025. PMID: 39972145
-
Robust Automated SIFT-MS Quantitation of Volatile Compounds in Air Using a Multicomponent Gas Standard.J Am Soc Mass Spectrom. 2023 Dec 6;34(12):2630-2645. doi: 10.1021/jasms.3c00312. Epub 2023 Nov 21. J Am Soc Mass Spectrom. 2023. PMID: 37988479 Free PMC article.
-
Recent developments and applications of selected ion flow tube mass spectrometry (SIFT-MS).Mass Spectrom Rev. 2025 Mar-Apr;44(2):101-134. doi: 10.1002/mas.21835. Epub 2023 Feb 12. Mass Spectrom Rev. 2025. PMID: 36776107 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources