Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2010 May 1;35(10):E392-5.
doi: 10.1097/BRS.0b013e3181cb4fcd.

Biomechanical comparison of three methods of sacral fracture fixation in osteoporotic bone

Affiliations
Comparative Study

Biomechanical comparison of three methods of sacral fracture fixation in osteoporotic bone

Simon C Mears et al. Spine (Phila Pa 1976). .

Abstract

Study design: Biomechanical cadaveric bench study.

Objective: To measure motion at the fracture site in an osteoporotic cadaveric sacral insufficiency fracture model before and after fracture creation, after fixation (via 1 of 3 fixation techniques), and after cyclic loading and to compare those values with motion of the intact pelvis.

Summary of background data: Sacral insufficiency fractures occur frequently in the elderly and pose treatment challenges. Screw fixation and sacroplasty have been proposed as possible treatments. There is little information about the stabilization provided by these treatments.

Methods: We potted 18 osteoporotic cadaveric pelves, mounted them on a materials testing machine, measured sacroiliac (SI) joint motion with a vertical load applied to the lumbar spine, and created simulated sacral insufficiency fractures. Then, we measured fracture site motion under load and repaired the fracture using 1 of 3 techniques: a unilateral SI screw, a bilateral SI screw, or sacroplasty. A vertical compressive load (10-350 N) was applied cyclically at 0.5 Hz to the lumbar spine of the repaired specimens for 5000 cycles. Kinematic analysis was conducted prefracture, postfracture, postrepair, and after cyclic loading.

Results: Postfracture, there was a significant increase in motion relative to the intact SI joint. After fixation, the average motion in all 3 groups was similar to that of the intact pelvis. After cyclical loading, motion increased in all groups. No significant differences were found between treatments.

Conclusion: All 3 fixation methods resulted acutely in motion similar to that of the intact pelvis. Although motion increased as a function of cyclical loading, no significant differences were found between fixation methods. All 3 repair methods reduced fracture site motion, but clinical studies are needed to determine if each method relieves pain and provides sufficient fixation for fracture healing.

PubMed Disclaimer

Similar articles

Cited by

Publication types

MeSH terms