Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2010 Jun;139(6):1473-1482.e5.
doi: 10.1016/j.jtcvs.2010.02.046. Epub 2010 Apr 14.

Surgical management of secondary tricuspid valve regurgitation: annulus, commissure, or leaflet procedure?

Affiliations
Free article
Comparative Study

Surgical management of secondary tricuspid valve regurgitation: annulus, commissure, or leaflet procedure?

Jose L Navia et al. J Thorac Cardiovasc Surg. 2010 Jun.
Free article

Abstract

Objectives: Techniques employed today concomitantly with left-sided heart valve surgery address secondary tricuspid valve regurgitation at 3 anatomic levels-annulus, commissure, and leaflet-although success of these alone or in combination in eliminating tricuspid regurgitation is uncertain. Our objective was to assess the comparative effectiveness of these techniques in reducing or eliminating secondary tricuspid regurgitation.

Methods: From 1990 to 2008, 2277 patients underwent tricuspid valve procedures for secondary tricuspid regurgitation concomitantly with mitral (n = 1527, 67%), aortic (n = 180, 7.9%), or combined (n = 570, 25%) valve surgery. These included annulus (flexible prosthesis [n = 1052, 46%], rigid prosthesis [standard = 387, 3-dimensional = 197; 26%], Peri-Guard annuloplasty [Synovis Surgical Innovations, St Paul, Minn; n = 185, 8.1%], and De Vega suture [n = 129, 5.7%]), commissure (Kay [n = 248, 11%]), and leaflet (edge-to-edge suture [n = 79, 3.5%] +/- annulus or commissural) procedures. A total of 4745 postoperative transthoracic echocardiograms in 1965 patients were analyzed.

Results: By 3 months after surgery, only 32% of patients overall had no tricuspid regurgitation. However, by 5 years, this had decreased to 22%, and 3+/4+ tricuspid regurgitation had increased from 11% at 3 months to 17%. Patients with rigid ring annuloplasty alone, either standard or 3-dimensional, had the least increase of 3+/4+ tricuspid regurgitation (to 12% at 5 years) compared with either a commissural or leaflet procedure.

Conclusion: Rigid prosthetic ring annuloplasty, standard or 3-dimensional, provides early and sustained reduction of tricuspid regurgitation secondary to left-sided valve disease without need for an additional leaflet procedure. However, results are imperfect, possibly because other anatomic levels (subvalvular, papillary muscle, and right ventricular) contributing to its pathophysiology are unaddressed.

PubMed Disclaimer

Comment in

  • Discussion.
    [No authors listed] [No authors listed] J Thorac Cardiovasc Surg. 2010 Jun;139(6):1481-2. doi: 10.1016/j.jtcvs.2010.02.048. Epub 2010 Apr 14. J Thorac Cardiovasc Surg. 2010. PMID: 20394949 No abstract available.

Publication types