. 2010 Sep 1;16(5):771-7.
doi: 10.1111/j.1365-2516.2010.02246.x. Epub 2010 Apr 8.

Thrombin generation in patients with factor XI deficiency and clinical bleeding risk

Affiliations

Thrombin generation in patients with factor XI deficiency and clinical bleeding risk

L Rugeri et al. Haemophilia. .

Abstract

Factor XI (FXI) deficiency is a rare bleeding disorder. Most patients with FXI deficiency are mild bleeders but certain patients with similar FXI activity exhibit different bleeding phenotype. Routine laboratory assays do not help physicians to estimate the individual bleeding risk in these patients. Thrombin generation test (TGT) is a more comprehensive, global function test of the clotting system. We investigated whether or not the bleeding tendency of patients with FXI deficiency is correlated with features of the TGT. Twenty-four patients with FXI deficiency were divided in two groups: (i) severe bleeders (n = 9) and (ii) mild or non-bleeders (n = 15). All severe bleeders had a personal history of surgery-related severe bleeding. Thrombin generation (TG) was measured in platelet-rich plasma (PRP) using a low concentration of tissue factor 0.5 pm. In patients exhibiting severe bleeding tendency, independently of their FXI level, a dramatically impaired TG was observed. For example, despite a low plasma FXI = 1 IU dl(-1), a clinically non-bleeding individual exhibited normal TG results whereas another patient with severe bleeding history and FXI = 40 IU dl(-1) had a very low TG capacity. Low velocity and delayed TG were the main parameters suggesting a higher bleeding risk. DNA analysis of patients reported eight novel mutations of the FXI gene but neither mutation location nor secretion or not of the variant correlated with the bleeding tendency. The results of this study suggest that TG measurement in PRP may be a useful tool to predict bleeding risk in FXI deficiency and should be studied further in larger prospective clinical studies.

PubMed Disclaimer

LinkOut - more resources