Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2010 Jul;17(7):841-8.
doi: 10.1016/j.acra.2010.02.011. Epub 2010 Apr 18.

Semiautomated segmentation of pleural effusions in MDCT datasets

Affiliations

Semiautomated segmentation of pleural effusions in MDCT datasets

Christian von Falck et al. Acad Radiol. 2010 Jul.

Abstract

Rationale and objectives: To develop and evaluate a novel algorithm for semiautomated segmentation and volumetry of pleural effusions in multidetector computed tomography (MDCT) datasets.

Materials and methods: A seven-step algorithm for semiautomated segmentation of pleural effusions in MDCT datasets was developed, mainly using algorithms from the ITK image processing library. Semiautomated segmentation of pleural effusions was performed in 40 MDCT datasets of the chest (males = 22, females = 18, mean age: 56.7 +/- 19.3 years). The accuracy of the semiautomated segmentation as compared with a manual segmentation approach was quantified based on the differences of the segmented volumes, the degree of over-/undersegmentation, and the Hausdorff distance. The time needed for the semiautomated and the manual segmentation process were recorded and compared.

Results: The mean volume of the pleural effusions was 557.30 mL (+/- 477.27 mL) for the semiautomated and 553.19 (+/- 473.49 mL) for the manual segmentation. The difference was not statistically significant (Student t-test, P = .133). Regression analysis confirmed a strong relationship between the semiautomated algorithm and the gold standard (r(2) = 0.998). Mean overlap of the segmented areas was 79% (+/- 9.3%) over all datasets with moderate oversegmentation (22% +/- 9.3%) and undersegmentation (21% +/- 9.7%). The mean Hausdorff distance was 17.2 mm (+/- 8.35 mm). The mean duration of the semiautomated segmentation process with user interaction was 8.4 minutes (+/- 2.6 minutes) as compared to 32.9 minutes (+/- 17.4 minutes) for manual segmentation.

Conclusion: The semiautomated algorithm for segmentation and volumetry of pleural effusions in MDCT datasets shows a high diagnostic accuracy when compared with manual segmentation.

PubMed Disclaimer

Similar articles

Cited by

MeSH terms