Lead in bone: sampling and quantitation using K X-rays excited by 109Cd
- PMID: 2040251
- PMCID: PMC1519364
- DOI: 10.1289/ehp.919149
Lead in bone: sampling and quantitation using K X-rays excited by 109Cd
Abstract
Lead in bone can be measured in vivo using gamma-rays from a 109Cd source to excite lead K X-rays. Normalization of lead X-ray amplitudes to that of the elastically backscattered 88 keV gamma-rays produces a determination of the concentration of lead in bone mineral that is accurate and insensitive to variations in measurement or bone geometry. For in vivo tibia measurements, a typical precision (1 SD) of +/- 5 micrograms lead (g bone mineral)-1 is achieved for an effective dose equivalent of 2.1 microSv. Measurement can be made of any superficial bone site, but precision will vary approximately as the inverse of the square root of the mass of bone mineral sampled. The apparatus required for this technique is readily transportable, and mobile laboratory facilities are easily established.
Similar articles
-
[Non-invasive determination of bone lead in human body using X-ray fluorescence excited by 109Cd].Guang Pu Xue Yu Guang Pu Fen Xi. 2004 Nov;24(11):1470-2. Guang Pu Xue Yu Guang Pu Fen Xi. 2004. PMID: 15762508 Chinese.
-
In vivo X-ray fluorescence of lead in bone using K X-ray excitation with 109Cd sources: radiation dosimetry studies.Environ Res. 1992 Apr;57(2):117-32. doi: 10.1016/s0013-9351(05)80073-8. Environ Res. 1992. PMID: 1568436
-
Factors affecting in vivo measurement precision and accuracy of 109Cd K x-ray fluorescence measurements.Phys Med Biol. 1999 Sep;44(9):2263-73. doi: 10.1088/0031-9155/44/9/313. Phys Med Biol. 1999. PMID: 10495120
-
In vivo X-ray fluorescence of lead in bone.Environ Res. 1992 Dec;59(2):326-35. doi: 10.1016/s0013-9351(05)80039-8. Environ Res. 1992. PMID: 1464286 Review.
-
In vivo X-ray fluorescence of lead in bone: review and current issues.Environ Health Perspect. 1994 Feb;102(2):172-7. doi: 10.1289/ehp.94102172. Environ Health Perspect. 1994. PMID: 8033846 Free PMC article. Review.
Cited by
-
Bone lead as a new biologic marker of lead dose: recent findings and implications for public health.Environ Health Perspect. 1998 Aug;106 Suppl 4(Suppl 4):961-7. doi: 10.1289/ehp.98106s4961. Environ Health Perspect. 1998. PMID: 9703479 Free PMC article.
-
Dosimetry Testing for a New In Vivo X-ray Fluorescence Measurement System.Health Phys. 2025 Apr 1;128(4):273-278. doi: 10.1097/HP.0000000000001839. Epub 2024 May 27. Health Phys. 2025. PMID: 39999410
-
Gender and race/ethnicity differences in lead dose biomarkers.Am J Public Health. 2008 Jul;98(7):1248-55. doi: 10.2105/AJPH.2007.118505. Epub 2008 May 29. Am J Public Health. 2008. PMID: 18511728 Free PMC article.
-
Validation of K-XRF bone lead measurement in young adults.Environ Health Perspect. 1995 Jan;103(1):78-83. doi: 10.1289/ehp.9510378. Environ Health Perspect. 1995. PMID: 7628429 Free PMC article.
-
Theoretical modeling of a portable x-ray tube based KXRF system to measure lead in bone.Physiol Meas. 2017 Mar;38(3):575-585. doi: 10.1088/1361-6579/aa5efe. Epub 2017 Feb 7. Physiol Meas. 2017. PMID: 28169835 Free PMC article.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources