Solid phase HLA antibody detection technology--challenges in interpretation
- PMID: 20403141
- DOI: 10.1111/j.1399-0039.2010.01486.x
Solid phase HLA antibody detection technology--challenges in interpretation
Abstract
The introduction into routine diagnostic laboratories of solid phase assays for human leukocyte antigen (HLA) antibody detection has resulted in the application of new laboratory matching algorithms in clinical organ transplantation which have improved pre-transplant detection of immunization, in turn resulting in avoidance of rejection in many cases which until their introduction would not have been possible using the historical complement dependent serological techniques. There have been two generations of solid phase assays introduced into routine practice, namely, the enzyme-linked immunosorbent assay (ELISA) technique and the use of fluorescent beads with HLA molecules bound to their surface which can either be used in conventional flow cytometry or in conjunction with Luminex instrumentation, the latter having become the most popular approach. The use of the fluorescent bead techniques has raised interesting questions both with respect to technical performance and the interpretation of the results obtained. The advantages of bead technology for HLA antibody determination and the technical issues requiring resolution are the subject of this review.
Similar articles
-
Consensus guidelines on the testing and clinical management issues associated with HLA and non-HLA antibodies in transplantation.Transplantation. 2013 Jan 15;95(1):19-47. doi: 10.1097/TP.0b013e31827a19cc. Transplantation. 2013. PMID: 23238534
-
Review article: Luminex technology for HLA antibody detection in organ transplantation.Nephrology (Carlton). 2009 Apr;14(2):247-54. doi: 10.1111/j.1440-1797.2008.01074.x. Nephrology (Carlton). 2009. PMID: 19207861 Review.
-
Reappraisal of HLA antibody analysis and crossmatching in kidney transplantation.Clin Transpl. 2007:219-26. Clin Transpl. 2007. PMID: 18642453
-
Solid phase assays for HLA antibody detection in clinical transplantation.Curr Opin Immunol. 2009 Oct;21(5):573-7. doi: 10.1016/j.coi.2009.07.017. Epub 2009 Sep 16. Curr Opin Immunol. 2009. PMID: 19765965 Review.
-
Prevalence and specificity of immunoglobulin G and immunoglobulin A non-complement-binding anti-HLA alloantibodies in retransplant candidates.Tissue Antigens. 2008 Jul;72(1):60-6. doi: 10.1111/j.1399-0039.2008.01067.x. Tissue Antigens. 2008. PMID: 18588575
Cited by
-
Anti-Human Leukocyte Antigen Antibody Detection from Terasaki's Humoral Theory to Delisting Strategies in 2024.Int J Mol Sci. 2025 Jan 13;26(2):630. doi: 10.3390/ijms26020630. Int J Mol Sci. 2025. PMID: 39859344 Free PMC article. Review.
-
Interpreting Anti-HLA Antibody Testing Data: A Practical Guide for Physicians.Transplantation. 2016 Aug;100(8):1619-28. doi: 10.1097/TP.0000000000001203. Transplantation. 2016. PMID: 27140516 Free PMC article. Review.
-
Utility of HLA Antibody Testing in Kidney Transplantation.J Am Soc Nephrol. 2015 Jul;26(7):1489-502. doi: 10.1681/ASN.2014080837. Epub 2015 Mar 24. J Am Soc Nephrol. 2015. PMID: 25804279 Free PMC article. Review.
-
Improvement in the definition of anti-HLA antibody profile in highly sensitized patients.PLoS One. 2017 Feb 3;12(2):e0171463. doi: 10.1371/journal.pone.0171463. eCollection 2017. PLoS One. 2017. PMID: 28158255 Free PMC article.
-
Many de novo donor-specific antibodies recognize β2 -microglobulin-free, but not intact HLA heterodimers.HLA. 2016 May;87(5):356-66. doi: 10.1111/tan.12775. Epub 2016 Apr 6. HLA. 2016. PMID: 27060279 Free PMC article.