Comparison of exercise electrocardiography, technetium-99m sestamibi single photon emission computed tomography, and dobutamine and dipyridamole echocardiography for detection of coronary artery disease in hypertensive women
- PMID: 20403475
- DOI: 10.1016/j.amjcard.2009.12.033
Comparison of exercise electrocardiography, technetium-99m sestamibi single photon emission computed tomography, and dobutamine and dipyridamole echocardiography for detection of coronary artery disease in hypertensive women
Abstract
To assess the performance of currently used stress tests for the detection of coronary artery disease (CAD) in a series of female hypertensive patients. We performed exercise electrocardiography (ECG), technetium-99m sestamibi (MIBI) single photon emission computed tomography, dobutamine and dipyridamole echocardiography, and coronary angiography in 76 hypertensive women. Of the 76 study patients, 31 (41%) had significant CAD. The sensitivity of exercise ECG (81%), MIBI scanning (90%), and dobutamine echocardiography (87%) was greater than that of dipyridamole echocardiography (61%). This finding resulted from the lower sensitivity of dipyridamole echocardiography in the detection of single-vessel CAD (47% vs 76%, 88%, and 82% for the other 3 methods). In contrast, the sensitivity of the 4 tests was similar in the detection of multivessel CAD. The specificity of exercise ECG (56%) and MIBI scanning (53%) was less than that of dobutamine (82%, both p <0.01) and dipyridamole (91%, both p <0.001) echocardiography. This finding related to the lower specificity of exercise ECG in patients with either left ventricular hypertrophy or ST-T abnormalities at rest compared to the specificity in patients without these disorders (33% vs 89%, p <0.01). A lower MIBI scan specificity was found only in patients with left ventricular hypertrophy (31% vs 66%, p <0.05). The overall accuracy of dobutamine echocardiography reached 84% compared to exercise ECG (66%, p <0.01), MIBI scan (68%, p <0.05), and dipyridamole echocardiography (79%, p <0.05). In conclusion, dobutamine echocardiography yielded satisfactory diagnostic accuracy for identifying CAD in hypertensive women. Although dipyridamole echocardiography had the greatest specificity, it might be limited in detecting mild CAD. Both exercise ECG and MIBI scanning had fare sensitivity; however, our findings limit the usefulness of these 2 tests in unselected patients.
Copyright 2010 Elsevier Inc. All rights reserved.
Similar articles
-
Accelerated stress real-time myocardial contrast echocardiography for the detection of coronary artery disease: comparison with 99mTc single photon emission computed tomography.J Am Soc Echocardiogr. 2008 Aug;21(8):941-7. doi: 10.1016/j.echo.2008.02.004. Epub 2008 Apr 2. J Am Soc Echocardiogr. 2008. PMID: 18385014
-
Comparison of stress/rest myocardial perfusion tomography, dipyridamole and dobutamine stress echocardiography for the detection of coronary disease in hypertensive patients with chest pain and positive exercise test.J Am Coll Cardiol. 1999 Aug;34(2):441-7. doi: 10.1016/s0735-1097(99)00231-4. J Am Coll Cardiol. 1999. PMID: 10440157
-
Optimize your use of stress tests: a Q&A guide.J Fam Pract. 2010 May;59(5):262-8. J Fam Pract. 2010. PMID: 20544045
-
Diagnosing coronary artery disease in patients with hypertension: a resolved dilemma?Ital Heart J. 2000 Nov;1(11):726-31. Ital Heart J. 2000. PMID: 11110514 Review.
-
Dobutamine stress myocardial perfusion imaging.J Am Coll Cardiol. 2000 Dec;36(7):2017-27. doi: 10.1016/s0735-1097(00)01012-3. J Am Coll Cardiol. 2000. PMID: 11127435 Review.
Cited by
-
Head to Head Comparison of Stress Echocardiography with Exercise Electrocardiography for the Detection of Coronary Artery Stenosis in Women.J Cardiovasc Ultrasound. 2016 Jun;24(2):135-43. doi: 10.4250/jcu.2016.24.2.135. Epub 2016 Jun 22. J Cardiovasc Ultrasound. 2016. PMID: 27358706 Free PMC article.
-
Myocardial perfusion scintigraphy and echocardiography for detecting coronary artery disease in hypertensive patients: a meta-analysis.Eur J Nucl Med Mol Imaging. 2011 Nov;38(11):2040-9. doi: 10.1007/s00259-011-1891-0. Epub 2011 Aug 4. Eur J Nucl Med Mol Imaging. 2011. PMID: 21814850
-
Gender differences in the diagnostic accuracy of SPECT myocardial perfusion imaging: a bivariate meta-analysis.J Nucl Cardiol. 2013 Feb;20(1):53-63. doi: 10.1007/s12350-012-9646-2. Epub 2012 Nov 13. J Nucl Cardiol. 2013. PMID: 23149886
-
Prediction of 8-year cardiovascular outcomes in patients with systemic arterial hypertension: value of stress (99m)Tc-tetrofosmin myocardial perfusion imaging in a high-risk cohort.J Nucl Cardiol. 2013 Dec;20(6):1030-40. doi: 10.1007/s12350-013-9790-3. Epub 2013 Oct 17. J Nucl Cardiol. 2013. PMID: 24132813
-
Diagnostic accuracy of non-invasive investigations for coronary artery disease in hypertensive patients: a meta-analysis.Arch Med Sci. 2024 Jun 6;21(1):167-178. doi: 10.5114/aoms/188782. eCollection 2025. Arch Med Sci. 2024. PMID: 40190327 Free PMC article. Review.