A Monte Carlo simulation of image misalignment effects in diffusion tensor imaging
- PMID: 20409661
- DOI: 10.1016/j.mri.2010.03.030
A Monte Carlo simulation of image misalignment effects in diffusion tensor imaging
Abstract
Diffusion tensor imaging (DTI) and tractography are noninvasive MRI methods, providing an insight on microscopic structural information of anisotropic tissues in vivo. The success of this technique stems on a watchful choice of imaging parameters and post-acquisition reconstruction. In the present work, we have focused on the problem of residual linear image misalignment in the DTI data and its effects on the parameters of the diffusion tensor and fiber tracking in human brain. We demonstrate substantial sensitivity of the reconstructed diffusion tensor and fiber tractography on increasing amplitude of artificially induced random image misalignment in the DTI. We show that already a submillimeter image misalignment in the DTI is an important source of error, which may potentially mask pathological presentations of the diseases and may partially explain variations in the results obtained from the DTI. Finally, we evaluated four implementations of image registrations and demonstrate their variable performance. This further supports the fact that a robust image registration must be performed to ensure reliable and reproducible diffusion tensor mapping and reconstruction of white matter (WM) fibers.
Copyright 2010 Elsevier Inc. All rights reserved.
Similar articles
-
Validation of the anisotropy index ellipsoidal area ratio in diffusion tensor imaging.Magn Reson Imaging. 2010 May;28(4):546-56. doi: 10.1016/j.mri.2009.12.015. Epub 2010 Jan 21. Magn Reson Imaging. 2010. PMID: 20096529
-
[Three-dimensional white matter tractography based on diffusion-tensor magnetic resonance imaging].Nan Fang Yi Ke Da Xue Xue Bao. 2007 Aug;27(8):1244-7. Nan Fang Yi Ke Da Xue Xue Bao. 2007. PMID: 17715038 Chinese.
-
A practical approach to in vivo high-resolution diffusion tensor imaging of rhesus monkeys on a 3-T human scanner.Magn Reson Imaging. 2009 Apr;27(3):335-46. doi: 10.1016/j.mri.2008.07.004. Epub 2008 Sep 2. Magn Reson Imaging. 2009. PMID: 18768280
-
Diffusion tractography: methods, validation and applications in patients with neurosurgical lesions.Neurosurg Clin N Am. 2011 Apr;22(2):253-68, ix. doi: 10.1016/j.nec.2010.11.004. Neurosurg Clin N Am. 2011. PMID: 21435575 Review.
-
MR diffusion kurtosis imaging for neural tissue characterization.NMR Biomed. 2010 Aug;23(7):836-48. doi: 10.1002/nbm.1506. NMR Biomed. 2010. PMID: 20623793 Review.
Cited by
-
Effect of increasing diffusion gradient direction number on diffusion tensor imaging fiber tracking in the human brain.Korean J Radiol. 2015 Mar-Apr;16(2):410-8. doi: 10.3348/kjr.2015.16.2.410. Epub 2015 Feb 27. Korean J Radiol. 2015. PMID: 25741203 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
