Accuracy of the newer generation intraocular lens power calculation formulas in long and short eyes
- PMID: 2040976
- DOI: 10.1016/s0886-3350(13)80249-0
Accuracy of the newer generation intraocular lens power calculation formulas in long and short eyes
Abstract
The accuracy of two newer generation theoretical intraocular lens (IOL) power calculation formulas and of the empirical SRK I and II formulas was evaluated in a series of 500 IOL implantations including a series of unusually long and short eyes. The prediction error of the theoretical formulas was found to be largely unaffected by the variation in axial length and corneal power, while the prediction of the SRK I formula was less accurate in the short and long eyes. The prediction of the SRK II formula was more accurate than the SRK I in that no systematic offset error with axial length could be demonstrated. However, because of a relatively larger scatter in the long eyes and a significant bias with the corneal power, the absolute error of the SRK II formula was higher than that of the theoretical formulas in the long eyes. The higher accuracy of the newer generation theoretical formulas was attributed to their improved prediction of the pseudophakic anterior chamber depth.
Similar articles
-
Intraocular lens power calculation with an improved anterior chamber depth prediction algorithm.J Cataract Refract Surg. 1995 May;21(3):313-9. doi: 10.1016/s0886-3350(13)80140-x. J Cataract Refract Surg. 1995. PMID: 7674170
-
Effect of anterior chamber depth on the choice of intraocular lens calculation formula in patients with normal axial length.Middle East Afr J Ophthalmol. 2014 Oct-Dec;21(4):307-11. doi: 10.4103/0974-9233.142266. Middle East Afr J Ophthalmol. 2014. PMID: 25371635 Free PMC article.
-
Achieving emmetropia in extremely short eyes with two piggyback posterior chamber intraocular lenses.Ophthalmology. 1996 Jul;103(7):1118-23. doi: 10.1016/s0161-6420(96)30558-7. Ophthalmology. 1996. PMID: 8684803
-
Meta-analysis of accuracy of intraocular lens power calculation formulas in short eyes.Clin Exp Ophthalmol. 2018 May;46(4):356-363. doi: 10.1111/ceo.13058. Epub 2017 Oct 10. Clin Exp Ophthalmol. 2018. PMID: 28887901 Review.
-
Accuracy of intraocular lens power calculation formulas in long eyes: a systematic review and meta-analysis.Clin Exp Ophthalmol. 2018 Sep;46(7):738-749. doi: 10.1111/ceo.13184. Epub 2018 Mar 24. Clin Exp Ophthalmol. 2018. PMID: 29498180
Cited by
-
Comparison of IOL power calculation formulae for pediatric eyes.Eye (Lond). 2016 Sep;30(9):1242-50. doi: 10.1038/eye.2016.171. Epub 2016 Aug 5. Eye (Lond). 2016. PMID: 27494083 Free PMC article.
-
New applications in ultrasound technology.Br J Ophthalmol. 1999 Nov;83(11):1246-9. doi: 10.1136/bjo.83.11.1246. Br J Ophthalmol. 1999. PMID: 10535849 Free PMC article. No abstract available.
-
Comparing the accuracy of the new-generation intraocular lens power calculation formulae in axial myopic eyes: a meta-analysis.Int Ophthalmol. 2023 Feb;43(2):619-633. doi: 10.1007/s10792-022-02466-4. Epub 2022 Sep 5. Int Ophthalmol. 2023. PMID: 36063246 Free PMC article.
-
Accuracy of intraocular lens power calculation in primary angle-closure disease: comparison of 7 formulas.Graefes Arch Clin Exp Ophthalmol. 2021 Dec;259(12):3739-3747. doi: 10.1007/s00417-021-05295-w. Epub 2021 Jul 14. Graefes Arch Clin Exp Ophthalmol. 2021. PMID: 34258655
-
Development of a program for toric intraocular lens calculation considering posterior corneal astigmatism, incision-induced posterior corneal astigmatism, and effective lens position.Graefes Arch Clin Exp Ophthalmol. 2016 Oct;254(10):1977-1986. doi: 10.1007/s00417-016-3446-3. Epub 2016 Aug 19. Graefes Arch Clin Exp Ophthalmol. 2016. PMID: 27541160