Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2010 Sep 6;411(17-18):1208-13.
doi: 10.1016/j.cca.2010.04.022. Epub 2010 Apr 26.

Plasma estrone sulfate assay in men: Comparison of radioimmunoassay, mass spectrometry coupled to gas chromatography (GC-MS), and liquid chromatography-tandem mass spectrometry (LC-MS/MS)

Affiliations
Free article
Comparative Study

Plasma estrone sulfate assay in men: Comparison of radioimmunoassay, mass spectrometry coupled to gas chromatography (GC-MS), and liquid chromatography-tandem mass spectrometry (LC-MS/MS)

Frank Giton et al. Clin Chim Acta. .
Free article

Abstract

Background: Estrogens are involved in the natural history of the prostate cancer and estrone sulfate, the quantitatively main circulating plasma estrogen in men, has been associated with an aggressive form of this cancer. A convenient and accurate plasma assay of this steroid has become important.

Methods: We simultaneously assayed estrone sulfate in the plasma of one hundred men aged 30-50 years, according to LC-MS/MS, GC-MS after solvolysis of E(1)S, radioimmunoassay after a chromatographic purification step, and a direct RIA commercial kit.

Results: Estrone sulfate plasma levels obtained with the first three methods were not significantly different. However, estrone sulfate levels measured by the direct RIA were three-fold higher than those obtained by the first three methods. We showed that the excessively high estrone sulfate levels obtained with the direct RIA kit had two origins: interference by high dehydroepiandrosterone sulfate plasma levels in men, and estrone sulfate inaccurate low concentrations in the standards.

Conclusion: The LC-MS/MS method can be considered as an optimum option for clinical laboratory. The GC-MS method requires solvolysis to estrone, but allows simultaneous unconjugated steroid measurement. RIA method, with chromatographic purification, is cumbersome, but less expensive. DSL-5400 kit yielded estrone sulfate plasma levels that were too high.

PubMed Disclaimer

Publication types