The effect of pH on rate constants, ion selectivity and thermodynamic properties of fluorescent calcium and magnesium indicators
- PMID: 2043105
- DOI: 10.1016/0006-291x(91)91966-g
The effect of pH on rate constants, ion selectivity and thermodynamic properties of fluorescent calcium and magnesium indicators
Abstract
Fluorescent calcium indicators fluo-3, fura-2 and indo-1, and fluorescent magnesium indicators mag-fura-2 (FURAPTRA) and mag-indo-1 were evaluated for the effects of pH on their association and dissociation rates, ion selectivity and thermodynamic properties. Calcium indicator affinities for Ca and Mg were reduced and the discrimination between Ca and Mg decreased in fura-2 and indo-1 at acidic pH. Alterations in apparent dissociation constants were caused primarily by reduced association rates. Magnesium indicators did not show these changes. The enthalphies of the calcium indicators' Ca complex were 1-3 kcal/mole and magnesium indicators' Mg complex were 7-9 kcal/mole. The potential effects of a biexponential dissociation rate of fluo-3 and of Ca interactions with magnesium indicators were examined.
Similar articles
-
The effects of pH and temperature on fluorescent calcium indicators as determined with Chelex-100 and EDTA buffer systems.Biochem Biophys Res Commun. 1990 Aug 31;171(1):102-8. doi: 10.1016/0006-291x(90)91362-v. Biochem Biophys Res Commun. 1990. PMID: 2118341
-
Measurement of free Zn2+ ion concentration with the fluorescent probe mag-fura-2 (furaptra).J Biochem Biophys Methods. 1993 Aug;27(1):25-37. doi: 10.1016/0165-022x(93)90065-v. J Biochem Biophys Methods. 1993. PMID: 8409208
-
A flow cytometric comparison of Indo-1 to fluo-3 and Fura Red excited with low power lasers for detecting Ca(2+) flux.J Immunol Methods. 2006 Apr 20;311(1-2):220-5. doi: 10.1016/j.jim.2006.02.005. Epub 2006 Mar 6. J Immunol Methods. 2006. PMID: 16545393
-
Chemical calcium indicators.Methods. 2008 Nov;46(3):143-51. doi: 10.1016/j.ymeth.2008.09.025. Epub 2008 Oct 16. Methods. 2008. PMID: 18929663 Free PMC article. Review.
-
Flow cytometric measurement of intracellular ionized calcium in single cells with indo-1 and fluo-3.Methods Cell Biol. 1990;33:37-58. doi: 10.1016/s0091-679x(08)60510-5. Methods Cell Biol. 1990. PMID: 2128108 Review. No abstract available.
Cited by
-
Effects of temperature on calcium-sensitive fluorescent probes.Biophys J. 2000 Apr;78(4):2116-26. doi: 10.1016/S0006-3495(00)76758-0. Biophys J. 2000. PMID: 10733989 Free PMC article.
-
Fluorescence lifetime characterization of magnesium probes: Improvement of Mg(2+) dynamic range and sensitivity using phase-modulation fluorometry.J Fluoresc. 1996 Jun;6(2):83-95. doi: 10.1007/BF00732047. J Fluoresc. 1996. PMID: 24227082 Free PMC article.
-
Dendritic calcium transients evoked by single back-propagating action potentials in rat neocortical pyramidal neurons.J Physiol. 1995 May 15;485 ( Pt 1)(Pt 1):1-20. doi: 10.1113/jphysiol.1995.sp020708. J Physiol. 1995. PMID: 7658365 Free PMC article.
-
Metal binding studies and EPR spectroscopy of the manganese transport regulator MntR.Biochemistry. 2006 Dec 26;45(51):15359-72. doi: 10.1021/bi0607406. Epub 2006 Nov 22. Biochemistry. 2006. PMID: 17176058 Free PMC article.
-
A new set of equations for the simplified calibration of fluorescence Ca2+ transients in skeletal muscle fibers.J Muscle Res Cell Motil. 2021 Jun;42(2):161-168. doi: 10.1007/s10974-021-09597-8. Epub 2021 Feb 17. J Muscle Res Cell Motil. 2021. PMID: 33595763
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Research Materials