CT-guided percutaneous large-bore biopsies in benign and malignant pediatric lesions
- PMID: 2044134
- DOI: 10.1007/BF02635536
CT-guided percutaneous large-bore biopsies in benign and malignant pediatric lesions
Abstract
Thirty-nine consecutive pediatric patients underwent large-bore biopsies of 41 lesions under computed tomography (CT) guidance; general anesthesia was not required. Adequate material was obtained in all patients. There were no false-negative or false-positive results. Typing accuracy was 100% in malignant disease and 92% in benign lesions. No significant complications occurred. Percutaneous large-bore biopsy is a safe, reliable, and time-saving method that obviates the need for open surgery and general anesthesia in the diagnosis of primarily non-resectable lesions, or lesions that do not require resection. Another major advantage over open surgery in malignant disease is the absence of delay in starting urgently needed chemotherapy.
Similar articles
-
[Percutaneous CT-guided cutting needle biopsy of pulmonary lesions: retrospective analysis of 153 procedures].Rev Med Chil. 2013 Apr;141(4):449-56. doi: 10.4067/S0034-98872013000400005. Rev Med Chil. 2013. PMID: 23900365 Spanish.
-
Accuracy of CT-guided percutaneous core needle biopsy for assessment of pediatric musculoskeletal lesions.Pediatr Radiol. 2011 Jul;41(7):848-57. doi: 10.1007/s00247-010-1970-6. Epub 2011 Jan 18. Pediatr Radiol. 2011. PMID: 21243347
-
[Technique and results of CT-guided percutaneous bone biopsy].Orthopade. 2001 Aug;30(8):545-50. doi: 10.1007/s001320170064. Orthopade. 2001. PMID: 11552396 German.
-
Percutaneous skeletal biopsy.Cardiovasc Intervent Radiol. 1991 Jan-Feb;14(1):69-72. doi: 10.1007/BF02635534. Cardiovasc Intervent Radiol. 1991. PMID: 2044132 Review.
-
Current role of computed tomography-guided transthoracic needle biopsy of metastatic lung lesions.Future Oncol. 2015;11(2 Suppl):43-6. doi: 10.2217/fon.14.258. Future Oncol. 2015. PMID: 25662328 Review.
Cited by
-
Modified Tru-Cut needle with exchangeable blunt stylet for safe puncture: technical note.Cardiovasc Intervent Radiol. 1992 Jul-Aug;15(4):251-3. doi: 10.1007/BF02733933. Cardiovasc Intervent Radiol. 1992. PMID: 1394364
-
Pathological diagnosis of paediatric tumours from image-guided needle core biopsies: a systematic review.Pediatr Radiol. 2006 May;36(5):426-31. doi: 10.1007/s00247-006-0123-4. Epub 2006 Mar 11. Pediatr Radiol. 2006. PMID: 16532346
-
Pediatric interventional radiology: current practice and innovations.Cardiovasc Intervent Radiol. 1993 Sep-Oct;16(5):267-74. doi: 10.1007/BF02629156. Cardiovasc Intervent Radiol. 1993. PMID: 8269421 Review.
References
MeSH terms
LinkOut - more resources
Medical