Determination of toxic elements in plastics from waste electrical and electronic equipment by slurry sampling electrothermal atomic absorption spectrometry
- PMID: 20441973
- DOI: 10.1016/j.talanta.2010.03.038
Determination of toxic elements in plastics from waste electrical and electronic equipment by slurry sampling electrothermal atomic absorption spectrometry
Abstract
Cadmium, chromium, lead and antimony were determined in slurries prepared using pulverized samples of personal computers and mobile phones dispersed in dimethylformamide medium. Determinations were carried out by electrothermal atomic absorption spectrometry (ETAAS) using a graphite furnace atomic absorption spectrometer. The optimization of the experimental conditions (chemical modifier, pyrolysis time, pyrolysis temperature and atomization temperatures) was accomplished by evaluating pyrolysis and atomization curves. Optimization was also used to determine the temperatures corresponding to the best sensitivities and the lowest background signals. The pyrolysis temperatures were fixed at 600 degrees C (for Cd), 700 degrees C (for Pb), 1100 degrees C (for Sb), and 1200 degrees C (for Cr); atomization temperatures were established as 1400 degrees C (for Cd), 1300 degrees C (for Pb), 1900 degrees C (for Sb), and 2300 degrees C (for Cr), and the chemical modifier (50microg NH(4)H(2)PO(4)+3microg Mg(NO(3))(2) was used for Cd and Pb while 5microg Pd+3microg Mg(NO(3))(2) was used for Sb). The use of a chemical modifier for Cr determination was not necessary. The characteristic masses were 1.9pg for Cd, 32.3pg for Pb, 54.1pg for Sb, and 9.1pg for Cr. Calibration was performed using standard additions in a range of 5-20microgL(-1) for Cd, 5-30microgL(-1) for Cr, 12.5-50microgL(-1) for Pb, and 25-100microgL(-1) for Sb with linear correlation coefficients higher than 0.99. Limits of detection were 0.9, 1.4, 6.8, and 2.9microgL(-1) for Cd, Pb, Sb, and Cr, respectively. The results indicate that recoveries for all metals agreed at a 95% confidence level when a paired t-test was applied and presented good precision. The accuracy of the proposed method was evaluated by addition-recovery experiments, showing results in the 96-112% range, and also by comparison of the results using Student's t-test with another method developed using ETAAS for digested samples. Analyte concentrations in the samples investigated varied from 5 to 525, 51 to 611, and 30 to 458mgkg(-1) for Cd, Cr, and Pb, respectively, while the content of Sb was in the 0.2-1.65% range.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources