The effect of the YK lens in keratoconus
- PMID: 20444133
- DOI: 10.1111/j.1475-1313.2010.00724.x
The effect of the YK lens in keratoconus
Abstract
Purpose: To report the clinical results of the use of the YK contact lens (Lucid Co., Seoul, Korea) for keratoconus.
Methods: One hundred and twenty nine keratoconic eyes were fitted with a YK lens which has one base curve and three peripheral curves. A light feather touch fluorescein pattern was obtained based on topographic indices. Visual acuity, comfort, mean wearing time, and ocular tissue changes were evaluated. Mean follow up was 17.5 +/- 13.8 months (range 6-75).
Results: One hundred and twenty six (97.6%) eyes tolerated the contact lenses. A total of 94.5% of the eyes achieved a visual acuity of 20/40 or better (average 0.79 +/- 0.21), and flatter base curve radius (BCR) was related to better visual acuity. One hundred and seventeen (90.7%) eyes reported that the lenses were comfortable. Mean wearing time was 12.1 h per day (range 4-18). Changes in keratometric values were not significant between baseline and final follow-up visit.
Conclusions: The YK lens can provide successful visual outcome, with comfort, and no significant influence on the progression of keratoconus.
Similar articles
-
Clinical performance and fitting characteristics with a multicurve lens for keratoconus.Eye Contact Lens. 2004 Jan;30(1):20-4. doi: 10.1097/01.ICL.0000095230.24618.03. Eye Contact Lens. 2004. PMID: 14722464
-
A retrospective case series: use of SoftPerm contact lenses in patients with keratoconus.Eye Contact Lens. 2007 Mar;33(2):103-5. doi: 10.1097/01.ICL.0000258592.12598.28. Eye Contact Lens. 2007. PMID: 17496704
-
Optimization of contact lens fitting in keratectasia patients after laser in situ keratomileusis.J Cataract Refract Surg. 2004 May;30(5):1057-66. doi: 10.1016/j.jcrs.2003.10.013. J Cataract Refract Surg. 2004. PMID: 15130644
-
Contact lens fitting in keratoconus.Compr Ophthalmol Update. 2006 Mar-Apr;7(2):47-52. Compr Ophthalmol Update. 2006. PMID: 16709339 Review.
-
The use of video-keratoscopy in predicting contact lens parameters for keratoconic fitting.Cont Lens Anterior Eye. 2010 Jun;33(3):112-8. doi: 10.1016/j.clae.2010.01.002. Epub 2010 Feb 4. Cont Lens Anterior Eye. 2010. PMID: 20129811 Review.
Cited by
-
Bevel toric multicurve rigid gas-permeable lens for keratoconus.Jpn J Ophthalmol. 2013 Mar;57(2):199-205. doi: 10.1007/s10384-012-0216-6. Epub 2012 Dec 7. Jpn J Ophthalmol. 2013. PMID: 23224726
-
Topographic progression of keratoconus in the Korean population.Korean J Ophthalmol. 2013 Jun;27(3):162-6. doi: 10.3341/kjo.2013.27.3.162. Epub 2013 May 3. Korean J Ophthalmol. 2013. PMID: 23730107 Free PMC article.
-
Current perspectives in the management of keratoconus with contact lenses.Eye (Lond). 2020 Dec;34(12):2175-2196. doi: 10.1038/s41433-020-1065-z. Epub 2020 Jul 8. Eye (Lond). 2020. PMID: 32641797 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical