Clinical benefit of hydroxyapatite-coated pins compared with stainless steel pins in external fixation at the wrist: a randomised prospective study
- PMID: 20444448
- DOI: 10.1016/j.injury.2010.03.030
Clinical benefit of hydroxyapatite-coated pins compared with stainless steel pins in external fixation at the wrist: a randomised prospective study
Abstract
Background: The purpose of this study was to determine the clinical benefit of hydroxyapatite (HA)-coated pins compared with standard stainless steel pins in external fixators applied for unstable fractures of the distal radius.
Methods: A total of 40 patients (160 pins) with unstable wrist fractures were randomised for uniplanar fixator treatment with the use of identically designed, commercially available pins either composed of stainless steel (steel group) (n = 20) or coated by hydroxyapatite (HA group) (n = 20). Each pin site was clinically evaluated concerning erythema and grade of drainage as well as pain intensity (numeric rating scale (NRS) 0–10) and, additionally, radiological assessment was performed concerning pin-loosening/infection as well as fracture healing at T1 (Ø18 days), T2 (Ø44 days) and T3 (Ø65 days). In case of pintrack complication, the patient was followed continuously. The need for intensified pin-site care, oral or intravenous antibiotic medication, re-admission for additional surgery and premature fixator removal was documented. Bone mineral density (BMD) was determined by dual energy X-ray absorptiometry. At fixator removal (T2), the pin-extraction strength was measured by the use of an electronic torque wrench.
Results: Two pin-track infections requiring daily pin-site care and oral antibiotics occurred in the HA group (2.6%) compared with four in the steel group (5.3%) (p = 0.601) and although a trend towards a superior performance of HA pins was detectable, the majority of clinical pin-site-parameters were comparable in both groups. At the end of the fixator therapy, the HA group showed a non-significant lower rate of loose pins (n(steel group) = 9; n(HA group) = 6; p = 0.864) and both hydroxyapatite-coated pins showed at the radius a significantly stronger pin-bone bonding measured by the torque wrench (p(proximal radius pin) = 0.007; p(distal radius pin) = 0.031). Except for elderly patients of the steel group (p = 0.018), all demographic-, health- and injury-related data including BMD were not correlated to any type of pin-site complication in both groups (p > 0.05). Since all fracture healed uneventfully without any type of additional surgery, the number of patients suffering clinically relevant pin-related complications showed no significant difference between both groups (p = 0.707).
Conclusions: The use of HA-coated pins compared with standard stainless-steel pins in external fixation for unstable wrist fractures yields only a trend towards a superior clinical outcome.
2010 Elsevier Ltd. All rights reserved.
Similar articles
-
Hydroxyapatite-coated pins versus titanium alloy pins in external fixation at the wrist: a controlled cohort study.J Trauma. 2011 Apr;70(4):845-51. doi: 10.1097/TA.0b013e3181e97761. J Trauma. 2011. PMID: 20805762 Clinical Trial.
-
Hydroxyapatite-coated external fixation pins.Expert Rev Med Devices. 2005 Jul;2(4):465-71. doi: 10.1586/17434440.2.4.465. Expert Rev Med Devices. 2005. PMID: 16293085 Review.
-
Titanium alloy pins versus stainless steel pins in external fixation at the wrist: a randomized prospective study.J Trauma. 2008 May;64(5):1275-80. doi: 10.1097/TA.0b013e31815e40e0. J Trauma. 2008. PMID: 18469650 Clinical Trial.
-
Enhanced fixation with hydroxyapatite coated pins.Clin Orthop Relat Res. 1998 Jan;(346):171-7. Clin Orthop Relat Res. 1998. PMID: 9577425 Clinical Trial.
-
Hydroxyapatite pins for external fixation: is there sufficient evidence to prove that coated pins are less likely to be replaced prematurely?Acta Orthop Traumatol Turc. 2015;49(4):410-5. doi: 10.3944/AOTT.2015.14.0206. Acta Orthop Traumatol Turc. 2015. PMID: 26312469 Review.
Cited by
-
Potential of Titanium Pins Coated with Fibroblast Growth Factor-2-Calcium Phosphate Composite Layers to Reduce the Risk of Impaired Bone-Pin Interface Strength in the External Fixation of Distal Radius Fractures.J Clin Med. 2024 May 22;13(11):3040. doi: 10.3390/jcm13113040. J Clin Med. 2024. PMID: 38892751 Free PMC article.
-
[Analysis of Microbiological Findings on the Surface of External Fixator Pins Comparing Steel Pins with Hydroxyapatite-Coated Pins].Rev Bras Ortop (Sao Paulo). 2025 Jun 23;60(2):1-7. doi: 10.1055/s-0045-1809519. eCollection 2025 Apr. Rev Bras Ortop (Sao Paulo). 2025. PMID: 40552005 Free PMC article. Portuguese.
-
Incidence and analysis of open fractures of the midshaft and distal femur.Wien Klin Wochenschr. 2013 Jul;125(13-14):396-401. doi: 10.1007/s00508-013-0391-6. Wien Klin Wochenschr. 2013. PMID: 23797531
-
Overview of methods for enhancing bone regeneration in distraction osteogenesis: Potential roles of biometals.J Orthop Translat. 2021 Feb 2;27:110-118. doi: 10.1016/j.jot.2020.11.008. eCollection 2021 Mar. J Orthop Translat. 2021. PMID: 33575164 Free PMC article. Review.
-
Improved bonding of partially osteomyelitic bone to titanium pins owing to biomimetic coating of apatite.Int J Mol Sci. 2013 Dec 13;14(12):24366-79. doi: 10.3390/ijms141224366. Int J Mol Sci. 2013. PMID: 24351822 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical