Perioperative myocardial perfusion scintigraphy at rest with technetium 99m methoxyisobutylisonitrile before and after coronary bypass operations
- PMID: 2044579
- DOI: 10.1007/BF00950754
Perioperative myocardial perfusion scintigraphy at rest with technetium 99m methoxyisobutylisonitrile before and after coronary bypass operations
Abstract
Eighteen patients were examined at rest by technetium 99m methoxyisobutylisonitrile (99mTc-MIBI) myocardial scintigraphy 1 day before and 1 week after aorto-coronary bypass operation with planar and single photon emission tomography (SPET) imaging. One day postoperatively, a planar scintigraph in the intensive care unit (ICU) was done. Inter-observer variability was 3.8% for all examinations and for SPET alone, 3.9%. The quality of the planar images taken under emergency conditions in the ICU was quite comparable with those taken under routine conditions. The postoperative myocardial infarction in a patient who died 6 days later could clearly be demonstrated. In 16.2% of all segments which were hypoperfused at rest on preoperative scintigraphy, an amelioration of perfusion could be shown in the 1st week after the bypass operation. 99mTc-MIBI proved to be a useful agent to assess perioperative perfusion, in the ICU as well as under standard conditions.
Similar articles
-
[Myocardial scintigraphy with Tc-99m-MIBI for assessing the extent and severity of coronary disease: a comparison with thallium-201 and equilibrium angiocardioscintigraphy].G Ital Cardiol. 1993 Feb;23(2):127-38. G Ital Cardiol. 1993. PMID: 8491353 Italian.
-
Role of technetium 99m methoxyisobutylisonitrile single photon emission tomography in the evaluation of thrombolysis in acute myocardial infarction before and after admission to hospital. Multicenter Study Group "Etude MIBI (EMIBI)".Eur J Nucl Med. 1991;18(2):91-8. doi: 10.1007/BF00950753. Eur J Nucl Med. 1991. PMID: 2044578
-
Fluorine-18 deoxyglucose PET for assessment of viable myocardium in perfusion defects in 99mTc-MIBI SPET: a comparative study in patients with coronary artery disease.Eur J Nucl Med. 1992;19(5):334-42. doi: 10.1007/BF00177055. Eur J Nucl Med. 1992. PMID: 1612095
-
Myocardial perfusion imaging with technetium-99m sestamibi SPECT in the evaluation of coronary artery disease.Am J Cardiol. 1990 Oct 16;66(13):55E-62E. doi: 10.1016/0002-9149(90)90613-6. Am J Cardiol. 1990. PMID: 2145748 Review.
-
The new 99mTc myocardial perfusion imaging agents: 99mTc-sestamibi and 99mTc-teboroxime.Circulation. 1991 Sep;84(3 Suppl):I7-21. Circulation. 1991. PMID: 1832100 Review.
Cited by
-
Prospective evaluation of thallium-201 reinjection in single-vessel coronary patients undergoing coronary bypass surgery.Eur J Nucl Med. 1993 Mar;20(3):213-8. doi: 10.1007/BF00170001. Eur J Nucl Med. 1993. PMID: 8462609
-
Changes in myocardial perfusion due to physical exercise in patients with stable coronary artery disease.Eur J Nucl Med Mol Imaging. 2005 Jul;32(7):813-9. doi: 10.1007/s00259-005-1768-1. Epub 2005 Mar 18. Eur J Nucl Med Mol Imaging. 2005. PMID: 15776230
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Medical