Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2010 Dec;24(12):3002-7.
doi: 10.1007/s00464-010-1076-0. Epub 2010 May 6.

Prospective evaluation of adhesion characteristics to intraperitoneal mesh and adhesiolysis-related complications during laparoscopic re-exploration after prior ventral hernia repair

Affiliations

Prospective evaluation of adhesion characteristics to intraperitoneal mesh and adhesiolysis-related complications during laparoscopic re-exploration after prior ventral hernia repair

Eric D Jenkins et al. Surg Endosc. 2010 Dec.

Abstract

Background: The purpose of this study was to characterize the adhesion characteristics of absorbable- and nonabsorbable-barrier-coated meshes and to report adhesiolysis-related complications during laparoscopic re-exploration after prior ventral hernia repair.

Methods: Under an IRB-approved protocol, patients undergoing laparoscopic re-exploration after prior intraperitoneal mesh placement were prospectively graded intraoperatively for adhesion tenacity (0-4), adhesion surface area (0 = 0%, 10 = 100%), and ratio of adhesiolysis time to mesh surface area (min/cm(2)). Adhesiolysis-related complications were also recorded. Data are given as mean ± SD. Statistical significance (P < 0.05) was determined using the t test and Fisher's exact test.

Results: From March 2006 to March 2009, 69 patients underwent laparoscopic surgery after prior intraperitoneal mesh placement for ventral hernia repair. Previous meshes were absorbable-barrier-coated mesh (n = 18), permanent-barrier composite mesh [Composix® (n = 17)], permanent-barrier noncomposite mesh [DualMesh® (n = 14)], uncoated polypropylene mesh (n = 12), and biologic mesh (n = 8). Indications for laparoscopic re-exploration were recurrent ventral hernia (n = 58), chronic pain (n = 3), cholecystectomy (n = 3), parastomal hernia (n = 2), small bowel obstruction (n = 1), nephrectomy (n = 1), and Nissen fundoplication (n = 1). Adhesions to DualMesh were less tenacious (P < 0.05) compared to all other meshes. Surface area of adhesions to DualMesh were less (P < 0.05) than to Composix and to uncoated polypropylene mesh, but not to absorbable-barrier-coated and biologic meshes. Adhesiolysis time:mesh surface area was less (P < 0.05) for DualMesh compared to Composix, uncoated polypropylene, and biologic mesh, but not to absorbable-barrier-coated mesh. Adhesiolysis-related complications occurred in two (16.7%) (P = ns) patients with uncoated polypropylene mesh, one cystotomy and one enterotomy; both were repaired laparoscopically. There were two (16.7%) (P = ns) conversions to an open procedure: one converted patient had Composix (6.7%) and one had absorbable-barrier-coated mesh (5.9%). There were no adhesiolysis-related complications with these meshes. There were no adhesiolysis-related complications or conversions to open in the DualMesh or biologic mesh groups.

Conclusions: Adhesion characteristics of mesh placed intraperitoneally and adhesiolysis-related complications during laparoscopic re-exploration after ventral hernia repair are associated with unique properties of the mesh and/or barrier.

PubMed Disclaimer

References

    1. Surg Innov. 2009 Mar;16(1):46-54 - PubMed
    1. Hernia. 2005 Mar;9(1):68-74 - PubMed
    1. Surg Endosc. 1999 Jan;13(1):10-3 - PubMed
    1. JSLS. 2003 Oct-Dec;7(4):335-40 - PubMed
    1. Ann Surg. 2003 Sep;238(3):391-9; discussion 399-400 - PubMed

LinkOut - more resources