The posterior approach reduces the risk of thin cement mantles with a straight femoral stem design
- PMID: 20446829
- PMCID: PMC2876829
- DOI: 10.3109/17453674.2010.487239
The posterior approach reduces the risk of thin cement mantles with a straight femoral stem design
Abstract
Background and purpose: The properties of the cement mantle around a prosthesis are important. We investigated whether the surgical approach to the hip influences the quality and thickness of the cement mantle when using a straight femoral stem design.
Methods: In a consecutive multi-surgeon series, we reviewed the radiographs of 270 patients after cemented Exeter total hip arthroplasty. 135 stems were introduced using an antero-lateral (transgluteal) approach and 135 stems were introduced using a posterior approach. Anterior-posterior and lateral radiographs were reviewed and cement mantle thickness was measured in Gruen zones 1-14. We graded cement mantle quality according to the Barrack classification.
Results: Barrack grading did not reveal any difference in cement mantle quality between the two groups. AP and lateral radiographs showed no difference in stem alignment between the groups. The risk of a thin cement mantle (< 2 mm) was lower with a posterior approach (OR = 1.8, 95% CI: 1-3; p = 0.03). The greatest risk of a cement mantle thickness of < 2 mm occurred in Gruen zones 8-9 regardless of the surgical approach used.
Interpretation: With a straight femoral stem design, the posterior approach to the hip joint appears to give a lower risk of a thin cement mantle. Irrespective of the approach, there was a risk of thin cement mantles in Gruen zones 8 and 9, which highlights the importance of lateral radiographs in the postoperative radiographic assessment of total hip replacements.
Comment in
-
Substantially higher prevalence of postoperative peri-prosthetic fractures in octogenarians with hip fractures operated with a cemented, polished tapered stem rather than an anatomic stem.Acta Orthop. 2016 Jun;87(3):257-61. doi: 10.3109/17453674.2016.1162898. Epub 2016 Apr 4. Acta Orthop. 2016. PMID: 27045318 Free PMC article.
References
-
- Anthony PP, Gie GA, Howie CR, Ling RSM. Localised endosteal bone lysis in relation to the femoral components of cemented total hip arthroplasties. J Bone Joint Surg (Br) 1990;72((6)):971–9. - PubMed
-
- Barrack RL, Mulroy RD, Harris WH. Improved cementing techniques and femoral component loosening in young patients with hip arthroplasty. J Bone Joint Surg (Br) 1992;74((3)):385–9. - PubMed
-
- Bartlett GE, Beard DJ, Murray DW, Gill HS. The femoral stem pump in cemented hip arthroplasty. An in vitro model. Med Eng Phys. 2008;30((8)):1042–8. - PubMed
-
- Berger RA, Steel MJ, Wood K, Evans RN, D'Antonio J, Rubash HE. Effect of a centralizing device on cement mantle deficiencies and initial prosthetic alignment in total hip arthroplasty. J Arthroplasty. 1997;12((4)):434–43. - PubMed
-
- Berli BJ, Schäfer D, Morscher EW. Ten-year survival of the MS-30 matt surfaced cemented stem. J Bone Joint Surg (Br) 2005;87((7)):928–33. - PubMed