Methacholine responsiveness, respiratory symptoms and pulmonary function in aluminum potroom workers
- PMID: 2044731
Methacholine responsiveness, respiratory symptoms and pulmonary function in aluminum potroom workers
Abstract
The relationship between nonspecific bronchial reactivity and work-related asthmatic symptoms was examined in a cross-sectional study of 337 aluminium potroom workers by a shortened method of continuous methacholine nebulization. The provocative concentration producing a 20% fall in forced expiratory volume in one second (FEV1) (PC20) was less than or equal to 8 mg.ml-1 (hyperresponsiveness) in 17 workers (5%), whilst minor responsiveness (8 mg.ml-1 less than PC20 less than 32 mg.ml-1) was present in 24 subjects (7%). The prevalence of work-related asthmatic symptoms was 9%. Female sex, ex-smoker and airflow limitation were significant predictors of methacholine responsiveness (p less than 0.05). In a multiple logistic regression analysis the odds ratios (OR) for work-related asthmatic symptoms was 10.8 (95% confidence interval: 2.9-40.6) for hyperresponsiveness and 4.4 (95% confidence interval: 1.2-16.4) for minor responsiveness. The sensitivity, specificity and predictivity of PC20 less than 32 mg.ml-1 for work-related asthmatic symptoms were 35, 92 and 35%, respectively, whilst the agreement, when adjusted for the by chance expectation, was 0.27 (95% confidence interval: 0.10-0.54). Although a significant association was found between bronchial reactivity and work-related asthmatic symptoms, the usefulness of the methacholine test as a tool for detection of work-related asthmatic symptoms appears to be of limited value due to its low sensitivity.
Similar articles
-
Bronchial responsiveness and work-related asthma in aluminium potroom workers: effect of removal from exposure.Eur Respir J. 1992 Jul;5(7):829-33. Eur Respir J. 1992. PMID: 1499706
-
Respiratory disorders in aluminium potroom workers.Med Lav. 1992 Sep-Oct;83(5):414-7. Med Lav. 1992. PMID: 1297049
-
Serial measurements of peak expiratory flow and responsiveness to methacholine in the diagnosis of aluminium potroom asthma.Thorax. 1992 Apr;47(4):292-7. doi: 10.1136/thx.47.4.292. Thorax. 1992. PMID: 1585295 Free PMC article.
-
Aluminium potroom asthma confirmed by monitoring of forced expiratory volume in one second.Am J Respir Crit Care Med. 1994 Dec;150(6 Pt 1):1714-7. doi: 10.1164/ajrccm.150.6.7952639. Am J Respir Crit Care Med. 1994. PMID: 7952639 Review.
-
Aluminium potroom asthma: the Norwegian experience.Eur Respir J. 1994 Jan;7(1):165-72. doi: 10.1183/09031936.94.07010165. Eur Respir J. 1994. PMID: 8143817 Review.
Cited by
-
Fluoride Exposure Induces Inhibition of Sodium-and Potassium-Activated Adenosine Triphosphatase (Na+, K+-ATPase) Enzyme Activity: Molecular Mechanisms and Implications for Public Health.Int J Environ Res Public Health. 2019 Apr 21;16(8):1427. doi: 10.3390/ijerph16081427. Int J Environ Res Public Health. 2019. PMID: 31010095 Free PMC article. Review.
-
Increased neutrophil chemotactic activity is noted in alminum-induced occupational asthma.Korean J Intern Med. 1996 Jan;11(1):69-73. doi: 10.3904/kjim.1996.11.1.69. Korean J Intern Med. 1996. PMID: 8882478 Free PMC article.
-
Lack of combined effects of exposure and smoking on respiratory health in aluminium potroom workers.Occup Environ Med. 1999 Jul;56(7):468-72. doi: 10.1136/oem.56.7.468. Occup Environ Med. 1999. PMID: 10472318 Free PMC article.
-
Bronchial responsiveness, eosinophilia, and short term exposure to air pollution.Arch Dis Child. 1995 Nov;73(5):418-22. doi: 10.1136/adc.73.5.418. Arch Dis Child. 1995. PMID: 8554358 Free PMC article.
-
Allergy to methyltetrahydrophthalic anhydride in epoxy resin workers.Br J Ind Med. 1992 Nov;49(11):769-75. doi: 10.1136/oem.49.11.769. Br J Ind Med. 1992. PMID: 1463677 Free PMC article.