Shear bond strength of orthodontic brackets bonded to various esthetic pontic materials
- PMID: 20451789
- DOI: 10.1016/j.ajodo.2008.06.031
Shear bond strength of orthodontic brackets bonded to various esthetic pontic materials
Abstract
Introduction: In this in-vitro study, we compared the shear bond strengths of orthodontic brackets bonded to various commonly used esthetic pontic materials.
Methods: Prefabricated denture teeth (acrylic resin, Trubyte, Dentsply, York, Pa) and samples made from Integrity (bis-acryl composite resin, Dentsply Caulk, Milford, Del) and Alike (polymethylmethacrylate resin, GC America, Alsip, Ill) were used to represent the more common esthetic provisional materials. Each material group contained 30 samples; a total of 90 samples were bonded in the same fashion with APC PLUS maxillary lateral incisor brackets (3M Unitek, Monrovia, Calif). Each material group was then divided into 2 testing subgroups. One subgroup was tested for shear bond strength 24 hours after bonding, and the other subgroup was tested after bonding and storage in distilled water at 37 degrees C for a week. Each bracket was loaded perpendicularly in a universal testing machine at a crosshead speed of 1.0 mm per minute until bonding failure. The mean shear bond strength and standard deviation were determined for each group. Analysis of variance (ANOVA, 2-factor and 1-factor) with Tukey HSD post-hoc tests, Student t tests, and Mann-Whitney U tests were used to test the main effects of pontic materials and time of loading (alpha = 0.05). The data were stratified, and 1-way ANOVA tests were performed with the Bonferroni adjustment (alpha = 0.01) to examine the effect of the pontic material on shear bond strength after either 1 day or 7 days of storage.
Results: Significant differences were found based on pontic material and time (P <0.05), but there was a significant interaction (P = 0.044), making the results uninterpretable. At 1 day, the Integrity material had a significantly higher mean shear bond strength than both Alike and the denture tooth materials (P <0.001). However, at 7 days, both Integrity and Alike had significantly higher mean shear bond strengths compared with the prefabricated denture tooth (P <0.001).
Conclusions: Although the use of Integrity or Alike requires an additional armamentarium, necessitating individual pontic fabrication by the dental practitioner, indications for clinical use are evident with direct applications to multi-disciplinary treatment modalities.
Copyright (c) 2010 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.
Similar articles
-
Should silane coupling agents be used when bonding brackets to composite restorations? An in vitro study.Eur J Orthod. 2009 Jun;31(3):266-70. doi: 10.1093/ejo/cjn106. Epub 2009 Feb 4. Eur J Orthod. 2009. PMID: 19193708 Clinical Trial.
-
Effects of surface conditioning on the shear bond strength of orthodontic brackets bonded to temporary polycarbonate crowns.Am J Orthod Dentofacial Orthop. 2010 Jul;138(1):72-8. doi: 10.1016/j.ajodo.2008.08.030. Am J Orthod Dentofacial Orthop. 2010. PMID: 20620836
-
Bond strength of orthodontic brackets with new self-adhesive resin cements.Am J Orthod Dentofacial Orthop. 2010 Apr;137(4):528-33. doi: 10.1016/j.ajodo.2008.04.027. Am J Orthod Dentofacial Orthop. 2010. PMID: 20362914
-
A comparison of three bracket bases: an in vitro study.Br J Orthod. 1991 Feb;18(1):29-35. doi: 10.1179/bjo.18.1.29. Br J Orthod. 1991. PMID: 1827348 Review.
-
Dental materials: 1993 literature review.J Dent. 1995 Apr;23(2):67-93. doi: 10.1016/0300-5712(95)98973-7. J Dent. 1995. PMID: 7738270 Review. No abstract available.
Cited by
-
Different Composite Veneer Surface Preparations for Metal Orthodontic Bracket Bonding: An In Vitro Study.Int J Dent. 2025 Jan 17;2025:2175748. doi: 10.1155/ijod/2175748. eCollection 2025. Int J Dent. 2025. PMID: 39866643 Free PMC article.
-
Evaluation of an alternative technique to optimize direct bonding of orthodontic brackets to temporary crowns.Dental Press J Orthod. 2015 Jul-Aug;20(4):57-62. doi: 10.1590/2176-9451.20.4.057-062.oar. Dental Press J Orthod. 2015. PMID: 26352846 Free PMC article.
-
Effect of surface treatment of prefabricated teeth on shear bond strength of orthodontic brackets.Dental Press J Orthod. 2017 Jul-Aug;22(4):47-52. doi: 10.1590/2177-6709.22.4.047-052.oar. Dental Press J Orthod. 2017. PMID: 28902249 Free PMC article.
-
Influence of cement type on the bond strength of orthodontic bands to zirconia crowns.BMC Oral Health. 2025 Mar 18;25(1):397. doi: 10.1186/s12903-025-05615-0. BMC Oral Health. 2025. PMID: 40102836 Free PMC article.
-
Does surface priming increase the bond strength of orthodontic brackets? An experimental study.Clin Exp Dent Res. 2024 Jun;10(3):e888. doi: 10.1002/cre2.888. Clin Exp Dent Res. 2024. PMID: 38712436 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Miscellaneous