Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2010 Jun;149(6):893-902.
doi: 10.1016/j.ajo.2010.01.025. Epub 2010 May 8.

Ahmed glaucoma valve and single-plate Molteno implants in treatment of refractory glaucoma: a comparative study

Affiliations
Randomized Controlled Trial

Ahmed glaucoma valve and single-plate Molteno implants in treatment of refractory glaucoma: a comparative study

Nader Nassiri et al. Am J Ophthalmol. 2010 Jun.

Abstract

Purpose: To report 2-year follow-up data after Ahmed valve implantation (New World Medical, Inc) and Molteno single-plate implantation surgical treatment of refractory glaucoma.

Design: Prospective, randomized, comparative study.

Methods: Patients with refractory glaucoma, defined as uncontrolled intraocular pressure (IOP) of more than 21 mm Hg despite maximal antiglaucoma medication, previously failed nonseton surgical treatment, or a combination thereof were included. Ninety-two patients were allocated randomly to each of the study groups and underwent implantation of either the Ahmed valve implant (model FP7; 184 mm(2) surface area) or Molteno single-plate implant (134 mm(2) surface area) and were followed up for 24 months. Main outcome measures were IOP and surgical success rate. Other outcome measures were changes in visual acuity, number of ant-glaucoma medications, mean deviation of visual field, and rate of intraoperative and postoperative complications.

Results: Those who successfully completed the trial (28 in the Molteno group and 29 in the Ahmed group) achieved significantly less IOP and fewer glaucoma medications, but worse visual acuity 24 months after surgery. The Molteno group, compared with the Ahmed group, achieved significantly lower IOPs after the early postoperative period until the end of the study. Both groups reasonably maintained visual field during the follow-up. The rate of surgical failure was comparable in both groups. Median survival time was 24 months for both groups. There were no devastating intraoperative or postoperative complications in either group.

Conclusions: Both Ahmed and Molteno implants successfully preserved visual field, although IOP control was more pronounced in the Molteno implant group.

PubMed Disclaimer

Comment in

  • Comparing glaucoma drainage implants.
    Gedde SJ, Lee RK. Gedde SJ, et al. Am J Ophthalmol. 2010 Jun;149(6):875-7. doi: 10.1016/j.ajo.2010.02.016. Am J Ophthalmol. 2010. PMID: 20510685 No abstract available.

Similar articles

Cited by

Publication types

Substances