Recent progress of flow-through optosensing in clinical and pharmaceutical analysis
- PMID: 20452162
- DOI: 10.1016/j.jpba.2010.04.020
Recent progress of flow-through optosensing in clinical and pharmaceutical analysis
Abstract
The applications of flow-through optosensing in clinical and pharmaceutical analysis in the last decade are here reviewed. A classification of the flow methodologies employed (conventional flow injection analysis, multicommutated flow analysis and sequential injection analysis) is introduced and their principal characteristics explained. The fundamentals of flow-through optosensing together with the main detection techniques are described and, later, the main applications of these flow methods are highlighted, paying special attention to the recent incorporation of new detection techniques in optosensing and to the design of multiparameter sensors. Finally, the advantages and disadvantages of the different flow methodologies here described are critically discussed.
Copyright (c) 2010 Elsevier B.V. All rights reserved.
Similar articles
-
Recent applications of flow-injection and sequential-injection analysis techniques to chemiluminescence determination of pharmaceuticals.J Pharm Biomed Anal. 2007 Nov 5;45(3):367-81. doi: 10.1016/j.jpba.2007.08.018. Epub 2007 Aug 21. J Pharm Biomed Anal. 2007. PMID: 17900844 Review.
-
Review of recent applications of flow injection spectrophotometry to pharmaceutical analysis.Anal Chim Acta. 2007 Apr 4;588(1):1-9. doi: 10.1016/j.aca.2007.01.060. Epub 2007 Jan 30. Anal Chim Acta. 2007. PMID: 17386786 Review.
-
[Amperometric detection in the determination of drugs by non-separating flow methods--flow injection analysis and sequential injection analysis].Ceska Slov Farm. 2001 May;50(3):107-12. Ceska Slov Farm. 2001. PMID: 11394017 Czech.
-
[Recent progress in flow-injection chemiluminescence for pharmaceutical analysis].Guang Pu Xue Yu Guang Pu Fen Xi. 2006 May;26(5):816-20. Guang Pu Xue Yu Guang Pu Fen Xi. 2006. PMID: 16883844 Review. Chinese.
-
Fluorimetric SIA optosensing in pharmaceutical analysis: determination of paracetamol.J Pharm Biomed Anal. 2007 Oct 18;45(2):318-21. doi: 10.1016/j.jpba.2007.05.004. Epub 2007 May 10. J Pharm Biomed Anal. 2007. PMID: 17587530
Cited by
-
Luminescence sensors applied to water analysis of organic pollutants--an update.Sensors (Basel). 2011;11(12):11081-102. doi: 10.3390/s111211081. Epub 2011 Nov 28. Sensors (Basel). 2011. PMID: 22247654 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical