Two-column sequential injection chromatography--new approach for fast and effective analysis and its comparison with gradient elution chromatography
- PMID: 20457303
- DOI: 10.1016/j.aca.2010.01.017
Two-column sequential injection chromatography--new approach for fast and effective analysis and its comparison with gradient elution chromatography
Abstract
This work presents novel approach in low-pressure chromatography flow systems--two-column Sequential Injection Chromatography (2-C SIC) and its comparison with gradient elution chromatography on the same instrument. The system was equipped with two different chromatographic columns (connected to selection valve in parallel design) for isocratic separation and determination of all components in composed anti-inflammatory pharmaceutical preparation (tablets). The sample was first injected on the first column of length 30 mm where less retained analytes were separated and then the sample was injected on the second column of length 10 mm where more retained analytes were separated. The SIC system was based on a commercial SIChrom manifold (8-port high-pressure selection valve and medium-pressure syringe pump with 4 mL reservoir) (FIAlab, USA) with two commercially available monolithic columns the "first column" Chromolith Flash RP-18e (25 mm x 4.6 mm i.d. with guard column 5 mm x 4.6 mm i.d.) and the "second column" Chromolith RP-18e (10 mm x 4.6 mm i.d.) and CCD UV-vis detector USB 4000 with micro-volume 1.0 cm Z flow cell. Two mobile phases were used for analysis (one for each column). The mobile phase 1 used for elution of paracetamol, caffeine and salicylic acid (internal standard) was acetonitrile/water (10:90, v/v, the water part of pH 3.5 adjusted with acetic acid), flow rate was 0.9 mL min(-1) (volume 3.0 mL of mobile phase per analysis). The mobile phase 2 used for elution of propyphenazone was acetonitrile/water (30:70, v/v); flow rate was 1.2 mL min(-1) (volume 1.5 mL of mobile phase per analysis). Absorbance was monitored at 210 nm. Samples were prepared by dissolving of one tablet in 30% acetonitrile and 10 microL of filtered supernatant was injected on each column (2 x 10 microL). The chromatographic resolution between all compounds was >1.45 and analysis time was 5.5 min under the optimal conditions. Limits of detection were determined at 0.4 microg mL(-1) for paracetamol, at 0.5 microg mL(-1) for caffeine and at 0.7 microg mL(-1) for propyphenazone. The new two-column chromatographic set-up developed as an alternative approach to gradient elution chromatography shows evident advantages (time and solvent reduction more than one-third) as compared with single-column gradient SIC method with Chromolith Flash RP-18 (25 mm x 4.6 mm i.d. with guard column 5 mm x 4.6 mm i.d.).
Copyright 2010 Elsevier B.V. All rights reserved.
Similar articles
-
Comparison of performance of C18 monolithic rod columns and conventional C18 particle-packed columns in liquid chromatographic determination of Estrogel and Ketoprofen gel.J Chromatogr B Analyt Technol Biomed Life Sci. 2004 Dec 25;813(1-2):191-7. doi: 10.1016/j.jchromb.2004.09.045. J Chromatogr B Analyt Technol Biomed Life Sci. 2004. PMID: 15556533
-
Enhanced capabilities of separation in Sequential Injection Chromatography--fused-core particle column and its comparison with narrow-bore monolithic column.Talanta. 2011 Aug 15;85(2):1129-34. doi: 10.1016/j.talanta.2011.05.027. Epub 2011 May 27. Talanta. 2011. PMID: 21726748
-
Optimization of the RP-HPLC method for multicomponent analgetic drug determination.Boll Chim Farm. 2003 Nov;142(9):386-9. Boll Chim Farm. 2003. PMID: 14971306
-
[Research advances in nano liquid chromatography instrumentation].Se Pu. 2021 Oct;39(10):1065-1076. doi: 10.3724/SP.J.1123.2021.06017. Se Pu. 2021. PMID: 34505428 Free PMC article. Review. Chinese.
-