Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2010 Mar;14(1):3-11.
doi: 10.1177/1084713810364396. Epub 2010 May 10.

Improvements in speech understanding with wireless binaural broadband digital hearing instruments in adults with sensorineural hearing loss

Affiliations
Randomized Controlled Trial

Improvements in speech understanding with wireless binaural broadband digital hearing instruments in adults with sensorineural hearing loss

Brian M Kreisman et al. Trends Amplif. 2010 Mar.

Abstract

This investigation examined whether speech intelligibility in noise can be improved using a new, binaural broadband hearing instrument system. Participants were 36 adults with symmetrical, sensorineural hearing loss (18 experienced hearing instrument users and 18 without prior experience). Participants were fit binaurally in a planned comparison, randomized crossover design study with binaural broadband hearing instruments and advanced digital hearing instruments. Following an adjustment period with each device, participants underwent two speech-in-noise tests: the QuickSIN and the Hearing in Noise Test (HINT). Results suggested significantly better performance on the QuickSIN and the HINT measures with the binaural broadband hearing instruments, when compared with the advanced digital hearing instruments and unaided, across and within all noise conditions.

PubMed Disclaimer

Figures

Figure 1.
Figure 1.
Audiometric data for new hearing aid users Circles represent mean thresholds. Lines represent one standard deviation.
Figure 2.
Figure 2.
Audiometric data for experienced hearing aid users Circles represent mean thresholds. Lines represent one standard deviation.
Figure 3.
Figure 3.
Coupler recordings for the Epoq XW
Figure 4.
Figure 4.
Coupler recordings for the Syncro V2
Figure 5.
Figure 5.
QuickSIN results for unaided, Syncro, and Epoq XW
Figure 6.
Figure 6.
Hearing in Noise Test (HINT) results for unaided, Syncro, and Epoq XW

References

    1. Allen J. B. (2005). Consonant recognition and the articulation index. Journal of the Acoustical Society of America, 117, 2212–2223 - PubMed
    1. American National Standards Institute. (1997). ANSI S3.5–1997, American national standard methods for calculation of the speech intelligibility index. New York: Author
    1. Best V., Carlile S., Craig J., van Schaik A. (2005). The role of high frequencies in speech localization. Journal of the Acoustical Society of America, 118, 353–363 - PubMed
    1. Boothroyd A., Medwetsky L. (1992). Spectral distribution of /s/ and the frequency response of hearing aids. Ear and Hearing, 13, 150–157 - PubMed
    1. Etymotic Research. (2001). QuickSIN: Speech-in-Noise Test (Version 1.3) [Audio CD]. Elk Grove Village, IL: Author

Publication types

MeSH terms