[Simultaneous assessment of wall motion and myocardial perfusion by technetium-99m methoxy isobutyl isonitrile]
- PMID: 2046186
[Simultaneous assessment of wall motion and myocardial perfusion by technetium-99m methoxy isobutyl isonitrile]
Abstract
The aim of this study was to assess whether or not myocardial uptake of Technetium-99m methoxy isobutyl isonitrile (Tc-MIBI) indicated myocardial viability. We performed simultaneous Tc-MIBI angiography and myocardial SPECT at rest on 12 patients with suspected coronary artery disease. Left ventricle was divided into 3 segments, and regional wall motion was graded as normal, hypokinesis and akinesis/dyskinesis. Myocardial uptake of Tc-MIBI was assessed as normal, reduced and absent in each segment. In segments with normal and reduced Tc-MIBI uptake, 7% (2 of 28) and 33% (2 of 6) showed wall motion abnormalities of akinesis/dyskinesis, respectively. However, all segments with absent Tc-MIBI uptake had asynergy of akinesis/dyskinesis (2 of 2, 100%). Myocardial Tc-MIBI uptake at rest indicated wall motion abnormalities and was considered to be useful for the evaluation of myocardial viability. First-pass radionuclide angiography followed by myocardial SPECT with Tc-MIBI demonstrated to be useful for the simultaneous assessment of the left ventricular wall motion and myocardial perfusion.
Similar articles
-
Simultaneous assessment of left ventricular wall motion and myocardial perfusion with technetium-99m-methoxy isobutyl isonitrile at stress and rest in patients with angina: comparison with thallium-201 SPECT.J Nucl Med. 1990 Apr;31(4):457-63. J Nucl Med. 1990. PMID: 2324821
-
Simultaneous assessment of left ventricular wall motion and myocardial perfusion at rest and during exercise by technetium-99m methoxy isobutyl isonitrile.Jpn Circ J. 1991 Dec;55(12):1192-9. doi: 10.1253/jcj.55.1192. Jpn Circ J. 1991. PMID: 1837319
-
Technetium-99m-labelled HL91 and technetium-99m-labelled MIBI SPECT imaging for the detection of ischaemic viable myocardium: a preliminary study.Clin Physiol Funct Imaging. 2012 Jan;32(1):25-32. doi: 10.1111/j.1475-097X.2011.01050.x. Epub 2011 Sep 29. Clin Physiol Funct Imaging. 2012. PMID: 22152075
-
Experimental studies of the physiologic properties of technetium-99m isonitriles.Am J Cardiol. 1990 Oct 16;66(13):5E-8E. doi: 10.1016/0002-9149(90)90605-z. Am J Cardiol. 1990. PMID: 2145747 Review.
-
Myocardial perfusion imaging with technetium-99m-labeled agents.Am J Cardiol. 1991 May 21;67(14):27D-34D. doi: 10.1016/s0002-9149(05)80005-0. Am J Cardiol. 1991. PMID: 1827941 Review.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources