Pushing the envelope: new computed tomography techniques for cardiothoracic imaging
- PMID: 20463530
- DOI: 10.1097/RTI.0b013e3181d7e898
Pushing the envelope: new computed tomography techniques for cardiothoracic imaging
Abstract
Multidetector row computed tomography (MDCT) has been used for cardiothoracic imaging since the advent of 4-slice computed tomography (CT) in 1999. Available since 2004, 64-slice CT systems are currently considered a prerequisite for successfully integrating cardiothoracic CT into routine clinical algorithms. Developments are ongoing that aim to solve the remaining challenges of cardiothoracic CT. In this review article, we focus on 3 aspects that have significantly influenced the design of newer CT scanners. (1) A faster scan speed enables coverage of the cardiothoracic anatomy in shorter scan times, which is beneficial for patients with limited ability to cooperate and opens new clinical possibilities. A coveted goal for cardiac CT is a "snapshot image" of the entire heart in 1 cardiac cycle, which can be obtained by using MDCT systems with area detectors or dual-source CT systems with electrocardiogram (ECG)-triggered high-pitch spiral. (2) Techniques to reduce the radiation dose to the patient, such as ECG-controlled dose modulation, ECG-triggered sequential CT, low kV scanning, and iterative reconstruction, have gained considerable attention as a consequence of the ongoing discussion of radiation exposure by CT. (3) New developments aim to establish a role for CT in the functional imaging of the lung and of the heart beyond the mere visualization of anatomy. Evaluation of the first-pass enhancement of the myocardium, with single-energy or with dual-energy data acquisition, and cardiac perfusion examinations may have the potential to enhance the application spectrum of cardiac CT by providing the means to determine the hemodynamic relevance of coronary artery stenosis.
Similar articles
-
Dose reduction in cardiothoracic CT: review of currently available methods.Radiographics. 2014 Oct;34(6):1469-89. doi: 10.1148/rg.346140084. Radiographics. 2014. PMID: 25310412 Review.
-
Noninvasive imaging of the coronary arteries using a 64-row multidetector CT scanner: initial clinical experience and radiation dose concerns.Radiol Med. 2007 Feb;112(1):31-46. doi: 10.1007/s11547-007-0118-8. Epub 2007 Feb 22. Radiol Med. 2007. PMID: 17310293 English, Italian.
-
Thoracic aorta: prospective electrocardiographically triggered CT angiography with dual-source CT--feasibility, image quality, and dose reduction.Radiology. 2010 Apr;255(1):207-17. doi: 10.1148/radiol.09090860. Epub 2010 Feb 16. Radiology. 2010. PMID: 20160003 Clinical Trial.
-
Iterative image reconstruction and its role in cardiothoracic computed tomography.J Thorac Imaging. 2013 Nov;28(6):355-67. doi: 10.1097/RTI.0000000000000054. J Thorac Imaging. 2013. PMID: 24149861 Review.
-
High-pitch electrocardiogram-triggered computed tomography of the chest: initial results.Invest Radiol. 2009 Nov;44(11):728-33. doi: 10.1097/RLI.0b013e3181b9df7e. Invest Radiol. 2009. PMID: 19809339
Cited by
-
Third-generation dual-source 70-kVp chest CT angiography with advanced iterative reconstruction in young children: image quality and radiation dose reduction.Pediatr Radiol. 2016 Apr;46(4):462-72. doi: 10.1007/s00247-015-3510-x. Epub 2016 Jan 6. Pediatr Radiol. 2016. PMID: 26739141
-
Energy Limits in Second Generation High-pitch Dual Source CT - Comparison in an Upper Abdominal Phantom.J Clin Imaging Sci. 2015 Jan 30;5:2. doi: 10.4103/2156-7514.150441. eCollection 2015. J Clin Imaging Sci. 2015. PMID: 25806137 Free PMC article.
-
Prognostic Value of CTA-Derived Left Ventricular Mass in Neonates with Congenital Heart Disease.Diagnostics (Basel). 2021 Jul 6;11(7):1215. doi: 10.3390/diagnostics11071215. Diagnostics (Basel). 2021. PMID: 34359298 Free PMC article.
-
Crown years for non-invasive cardiovascular imaging (Part IV): 30 years of cardiac computed tomography.Neth Heart J. 2013 Jul;21(7-8):315-8. doi: 10.1007/s12471-013-0427-6. Neth Heart J. 2013. PMID: 23640578 Free PMC article. No abstract available.
-
Utility of dual source CT with ECG-triggered high-pitch spiral acquisition (Flash Spiral Cardio mode) to evaluate morphological features of ventricles in children with complex congenital heart defects.Jpn J Radiol. 2016 Apr;34(4):284-91. doi: 10.1007/s11604-016-0522-x. Epub 2016 Jan 28. Jpn J Radiol. 2016. PMID: 26820980
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical