Abstract
Object: The purpose of this paper was to present the safety, efficacy, and clinical/angiographic follow-up results of HyperForm balloon-assisted endosaccular coil occlusion of distal anterior circulation bifurcation aneurysms.
Methods: Over a 7-year period, the authors treated 864 middle cerebral artery, distal anterior cerebral artery bifurcation, and anterior communicating artery aneurysms by means of coil embolization with HyperForm balloon assistance in 800 patients. In 37 aneurysms, 2 HyperForm balloons were used simultaneously for remodeling.
Results: The overall mortality rate was 7.1%, including 1.4% procedural mortality. Various neurological deficits were present at discharge in 8.9% of the patients, and 4.4% had permanent disabling morbidity 6 months posttreatment (modified Rankin Scale score ≥ 2). Thromboembolic complications developed during the treatment of 15 aneurysms (1.7%) causing morbidity or mortality in 10 cases (1.3%). There were 14 intraoperative perforations (1.6%). In all 14 cases, the HyperForm balloon saved patients from severe bleeding. The perforation led to morbidity or mortality in 3 cases (0.4%); there were no negative consequences in 11. There were 726 patients with 757 aneurysms (87.6%) available for follow-up. Control angiograms were obtained at 6 months in 386 patients, at 1 year in 267, and at 2 years in 104, revealing an 82% complete obliteration rate according to the most recent follow-up angiograms.
Conclusions: The satisfactory results obtained in this experience demonstrate that HyperForm balloon remodeling provides strong benefits for the endovascular management of middle cerebral, anterior cerebral, and anterior communicating artery aneurysms without increasing the risk of treatment. Not only does this technique allow for the safe treatment of these aneurysms, but it also expands the indications of endovascular treatment to include aneurysms that otherwise cannot be treated with simple coil embolization.
Comment in
-
Balloon remodeling.J Neurosurg. 2011 Apr;114(4):942-3; discussion 943. doi: 10.3171/2010.2.JNS091556. Epub 2010 May 14. J Neurosurg. 2011. PMID: 20469987 No abstract available.
Similar articles
-
Endovascular treatment of proximal and distal posterior inferior cerebellar artery aneurysms.J Neurosurg. 2013 May;118(5):991-9. doi: 10.3171/2012.12.JNS121240. Epub 2013 Jan 25. J Neurosurg. 2013. PMID: 23350778
-
A single-centre experience and follow-up of patients with endovascular coiling of large and giant intracranial aneurysms with parent artery preservation.J Clin Neurosci. 2012 Mar;19(3):364-9. doi: 10.1016/j.jocn.2011.03.038. Epub 2012 Jan 25. J Clin Neurosci. 2012. PMID: 22277568
-
Bypass surgery for complex middle cerebral artery aneurysms: impact of the exact location in the MCA tree.J Neurosurg. 2014 Feb;120(2):398-408. doi: 10.3171/2013.10.JNS13738. Epub 2013 Nov 29. J Neurosurg. 2014. PMID: 24286147
-
Anterior cerebral artery bypass for complex aneurysms: an experience with intracranial-intracranial reconstruction and review of bypass options.J Neurosurg. 2014 Jun;120(6):1364-77. doi: 10.3171/2014.3.JNS132219. Epub 2014 Apr 18. J Neurosurg. 2014. PMID: 24745711 Review.
-
Endovascular treatment of previously clipped aneurysms: continued evolution of hybrid neurosurgery.J Neurointerv Surg. 2017 Feb;9(2):169-172. doi: 10.1136/neurintsurg-2016-012625. Epub 2016 Aug 8. J Neurointerv Surg. 2017. PMID: 27502402 Review.
Cited by
-
Initial experience with the coaxial dual-lumen ascent balloon catheter for wide-neck aneurysm coil embolization.Front Neurol. 2011 Aug 19;2:52. doi: 10.3389/fneur.2011.00052. eCollection 2011. Front Neurol. 2011. PMID: 21897828 Free PMC article.
-
Endovascular Management of Hemorrhagic Stroke.Biomedicines. 2022 Jan 4;10(1):100. doi: 10.3390/biomedicines10010100. Biomedicines. 2022. PMID: 35052779 Free PMC article. Review.
-
A Prospective Multicenter Trial of the TransForm Occlusion Balloon Catheter: Trial Design and Results.Interv Neurol. 2018 Feb;7(1-2):53-64. doi: 10.1159/000481518. Epub 2017 Nov 15. Interv Neurol. 2018. PMID: 29628946 Free PMC article.
-
Initial experience of intracranial aneurysm embolization using the balloon remodeling technique with Scepter C, a new double-lumen balloon.Interv Neuroradiol. 2012 Sep;18(3):284-7. doi: 10.1177/159101991201800306. Epub 2012 Sep 10. Interv Neuroradiol. 2012. PMID: 22958766 Free PMC article.
-
REtrieving thrombi and Separated Coils/catheters Unexpectedly detached during Endovascular therapy: RESCUE - the use of thrombectomy devices for rescue therapy in interventional neuroradiology.Interv Neuroradiol. 2024 Dec 19:15910199241299139. doi: 10.1177/15910199241299139. Online ahead of print. Interv Neuroradiol. 2024. PMID: 39699019 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical