Verification of the efficiency of chemical disinfection and sanitation measures in in-building distribution systems
- PMID: 20472500
- DOI: 10.1016/j.ijheh.2010.04.006
Verification of the efficiency of chemical disinfection and sanitation measures in in-building distribution systems
Abstract
Previous investigations of biofilms, generated in a silicone tube model have shown that the number of colony forming units (CFU) can reach 10(7)/cm(2), the total cell count (TCC) of microorganisms can be up to 10(8)cells/cm(2). The present study focuses on the situation in in-building distribution systems. Different chemical disinfectants were tested for their efficacy on drinking water biofilms in silicone tubes: free chlorine (electrochemically activated), chlorine dioxide, hydrogen peroxide (H(2)O(2)), silver, and fruit acids. With regard to the widely differing manufacturers' instructions for the usage of their disinfectants three different variations of the silicone tube model were developed to simulate practical use conditions. First the continuous treatment, second the intermittent treatment, third the efficacy of external disinfection treatment and the monitoring for possible biofilm formation with the Hygiene-Monitor. The working experience showed that it is important to know how to handle the individual disinfectants. Every active ingredient has its own optimal application concerning its concentration, exposure time, physical parameters like pH, temperature or redox potential. When used correctly all products tested were able to reduce the CFU to a value below the detection limit. Most of the active ingredients could not significantly reduce the TCC/cm(2), which means that viable microorganisms may still be present in the system. Thus the question arises what happened with these cells? In some cases SEM pictures of the biofilm matrix after a successful disinfection still showed biofilm residues. According to these results, no general correlation between CFU/cm(2), TCC/cm(2) and the visualised biofilm matrix on the silicone tube surface (SEM) could be demonstrated after a treatment with disinfectants.
Copyright 2010 Elsevier GmbH. All rights reserved.
Similar articles
-
Long-term effects of disinfectants on the community composition of drinking water biofilms.Int J Hyg Environ Health. 2010 Jun;213(3):183-9. doi: 10.1016/j.ijheh.2010.04.007. Epub 2010 May 21. Int J Hyg Environ Health. 2010. PMID: 20494617
-
Influence of biofilms by chemical disinfectants and mechanical cleaning.Zentralbl Bakteriol Mikrobiol Hyg B Umwelthyg Krankenhaushyg Arbeitshyg Prav Med. 1987 Apr;183(5-6):549-63. Zentralbl Bakteriol Mikrobiol Hyg B Umwelthyg Krankenhaushyg Arbeitshyg Prav Med. 1987. PMID: 3109156
-
A model system for evaluating surface disinfection in dairy factory environments.Int J Food Microbiol. 2010 Feb 28;137(2-3):161-7. doi: 10.1016/j.ijfoodmicro.2009.11.028. Epub 2009 Dec 3. Int J Food Microbiol. 2010. PMID: 20022125
-
Microbial biofilm formation in DUWS and their control using disinfectants.J Dent. 2007 Sep;35(9):721-30. doi: 10.1016/j.jdent.2007.07.005. Epub 2007 Aug 21. J Dent. 2007. PMID: 17714847 Review.
-
Fresh-cut product sanitation and wash water disinfection: problems and solutions.Int J Food Microbiol. 2009 Aug 31;134(1-2):37-45. doi: 10.1016/j.ijfoodmicro.2009.05.021. Epub 2009 May 25. Int J Food Microbiol. 2009. PMID: 19539390 Review.
Cited by
-
Long-Term Bacterial Dynamics in a Full-Scale Drinking Water Distribution System.PLoS One. 2016 Oct 28;11(10):e0164445. doi: 10.1371/journal.pone.0164445. eCollection 2016. PLoS One. 2016. PMID: 27792739 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical