Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2010 Nov;138(5):1062-70.
doi: 10.1378/chest.09-2690. Epub 2010 May 14.

Cutaneous ear lobe Pco₂ at 37°C to evaluate microperfusion in patients with septic shock

Affiliations
Comparative Study

Cutaneous ear lobe Pco₂ at 37°C to evaluate microperfusion in patients with septic shock

Fabrice Vallée et al. Chest. 2010 Nov.

Abstract

Background: Tissue hypercarbia is related to hypoperfusion and microcirculatory disturbances in patients with septic shock. Transcutaneous Pco₂ devices using a heated sensor to arterialize the tissue have been used as an alternative method for estimation of Paco₂. This study investigates whether a cutaneous sensor attached to an ear lobe and regulated to 37°C could be used to measure cutaneous Pco₂ (Pcco₂) and evaluate microperfusion in patients with septic shock.

Methods: Fifteen stable patients in an ICU were studied as a control group. Forty-six patients with septic shock who were ventilated were enrolled as the study group. The difference of the gradients between Pcco₂ and Paco₂ (Pc-aco₂) and between Pcco₂ and end-tidal Pco₂(Pc-etco₂) were evaluated for 36 h. Variations of the Pc-aco₂ and Pc-etco₂ during fluid challenge were compared with microcirculatory skin blood flow (mBFskin) assessed by laser Doppler flowmetry.

Results: The baseline levels for Pc-aco₂ and Pc-etco₂ were significantly higher in the patients with septic shock than in the control group (14.8 [12.6] vs 6 [2.7] mm Hg and 25 [16.3] vs 9 [3.8] mm Hg, P < .0001, respectively). During the following 36 h, the Pc-aco₂ and Pc-etco₂ for the surviving patients with septic shock decreased significantly compared with the nonsurvivors (P < .01). The evolution of macrohemodynamic parameters showed no differences between survivors and nonsurvivors. At hour 24, a Pc-aco₂ > 16 mm Hg and a Pc-etco₂ > 26 mm Hg were related to poor outcome. Pc-aco₂ and Pc-etco₂ variations during fluid challenge were inversely correlated with changes in mBFskin (r² = 0.7).

Conclusions: Ear lobe cutaneous Pco₂ at 37°C represents a noninvasive technique to assess tissue Pco₂ measurement. Pc-aco₂ and Pc-etco₂ were related to outcome and provide continuous information on microperfusion in patients with septic shock.