Relationship between pulse transit time and blood pressure is impaired in patients with chronic heart failure
- PMID: 20473677
- DOI: 10.1007/s00392-010-0168-0
Relationship between pulse transit time and blood pressure is impaired in patients with chronic heart failure
Abstract
Aims: Pulse transit time (PTT), the interval between ventricular electrical activity and arrival of the peripheral pulse wave, has been used to detect changes in autonomic tone during sleep and anesthesia. The purpose of this study was to evaluate PTT in patients with chronic heart failure (HF).
Methods and results: Pulse transit time was measured with R-wave gated photoplethysmography in 24 healthy volunteers and in 112 patients with chronic HF and ejection fraction (EF) <40%. PTT was mildly elevated in patients with HF (468 ± 12 vs. 430 ± 23 ms, p = 0.001). In healthy volunteers, PTT was directly proportional to blood pressure (BP): when BP increased, PTT shortened, and vice versa. This relationship between PTT and BP (PTTi) was altered in patients with HF and particularly in the 26 patients with decompensated HF (3.6 ± 0.4 vs. 4.2 ± 0.9, p = 0.04). PTTi did not correlate with functional NYHA class and levels of pro-BNP, epinephrine or norepinephrine. There was a modest correlation between PTTi and EF (p = 0.01, r = -0.48) and PTTi tended to correlate with microvascular flow measured with Laser Doppler (p = 0.08). However, there was an excellent correlation between PTTi and systolic time intervals, left ventricular ejection time (LVET) (p = 0.0014, r = -0.75) and pre-ejection time/LVET (p = 0.006, r = 0.80). The latter ratio reflects ventricular-arterial coupling.
Conclusion: The relationship between PTT and BP is altered in severe HF and may indicate impaired ventricular-arterial coupling. It merits further investigation as both parameters can be easily determined and used for serial monitoring in HF.
Similar articles
-
Beat-to-beat tracking of systolic blood pressure using noninvasive pulse transit time during anesthesia induction in hypertensive patients.Anesth Analg. 2013 Jan;116(1):94-100. doi: 10.1213/ANE.0b013e318270a6d9. Epub 2012 Dec 7. Anesth Analg. 2013. PMID: 23223109
-
Comparison of noninvasive pulse transit time estimates as markers of blood pressure using invasive pulse transit time measurements as a reference.Physiol Rep. 2016 May;4(10):e12768. doi: 10.14814/phy2.12768. Physiol Rep. 2016. PMID: 27233300 Free PMC article.
-
Validity of transit time-based blood pressure measurements in patients with and without heart failure or pulmonary arterial hypertension across different breathing maneuvers.Sleep Breath. 2020 Mar;24(1):221-230. doi: 10.1007/s11325-019-01848-w. Epub 2019 May 2. Sleep Breath. 2020. PMID: 31049851
-
Pulse transit time by R-wave-gated infrared photoplethysmography: review of the literature and personal experience.J Clin Monit Comput. 2004 Dec;18(5-6):333-42. doi: 10.1007/s10877-005-4300-z. J Clin Monit Comput. 2004. PMID: 15957624 Review.
-
Relation between heart rate and pulse transit time during paced respiration.Physiol Meas. 2001 Aug;22(3):425-32. doi: 10.1088/0967-3334/22/3/301. Physiol Meas. 2001. PMID: 11556663 Review.
Cited by
-
Intraoperative Beat-to-Beat Pulse Transit Time (PTT) Monitoring via Non-Invasive Piezoelectric/Piezocapacitive Peripheral Sensors Can Predict Changes in Invasively Acquired Blood Pressure in High-Risk Surgical Patients.Sensors (Basel). 2023 Mar 21;23(6):3304. doi: 10.3390/s23063304. Sensors (Basel). 2023. PMID: 36992016 Free PMC article.
-
Filtering-induced changes of pulse transmit time across different ages: a neglected concern in photoplethysmography-based cuffless blood pressure measurement.Front Physiol. 2023 Jul 25;14:1172150. doi: 10.3389/fphys.2023.1172150. eCollection 2023. Front Physiol. 2023. PMID: 37560157 Free PMC article.
-
Validation of blood pressure monitoring using pulse transit time in heart failure patients with Cheyne-Stokes respiration undergoing adaptive servoventilation therapy.Sleep Breath. 2014 May;18(2):411-21. doi: 10.1007/s11325-013-0895-3. Epub 2013 Sep 24. Sleep Breath. 2014. PMID: 24062012
-
Continuous Blood Pressure Estimation From Electrocardiogram and Photoplethysmogram During Arrhythmias.Front Physiol. 2020 Sep 9;11:575407. doi: 10.3389/fphys.2020.575407. eCollection 2020. Front Physiol. 2020. PMID: 33013491 Free PMC article.
-
Increasing accuracy of pulse transit time measurements by automated elimination of distorted photoplethysmography waves.Med Biol Eng Comput. 2017 Nov;55(11):1989-2000. doi: 10.1007/s11517-017-1642-x. Epub 2017 Mar 30. Med Biol Eng Comput. 2017. PMID: 28361357 Free PMC article.
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Research Materials
Miscellaneous