Mechanical ventilation and the total artificial heart: optimal ventilator trigger to avoid post-operative autocycling - a case series and literature review
- PMID: 20478064
- PMCID: PMC2893170
- DOI: 10.1186/1749-8090-5-39
Mechanical ventilation and the total artificial heart: optimal ventilator trigger to avoid post-operative autocycling - a case series and literature review
Abstract
Many patients with end-stage cardiomyopathy are now being implanted with Total Artificial Hearts (TAHs). We have observed individual cases of post-operative mechanical ventilator autocycling with a flow trigger, and subsequent loss of autocycling after switching to a pressure trigger. These observations prompted us to do a retrospective review of all TAH devices placed at our institution between August 2007 and May 2009. We found that in the immediate post-operative period following TAH placement, autocycling was present in 50% (5/10) of cases. There was immediate cessation of autocycling in all patients after being changed from a flow trigger of 2 L/minute to a pressure trigger of 2 cm H2O. The autocycling group was found to have significantly higher CVP values than the non-autocycling group (P = 0.012). Our data suggest that mechanical ventilator autocycling may be resolved or prevented by the use of a pressure trigger rather than a flow trigger setting in patients with TAHs who require mechanical ventilation.
Figures
Similar articles
-
Airway leak size in neonates and autocycling of three flow-triggered ventilators.Crit Care Med. 1995 Oct;23(10):1739-44. doi: 10.1097/00003246-199510000-00020. Crit Care Med. 1995. PMID: 7587241
-
Ventilator autocycling due to an endotracheal tube cuff leak.Chest. 1991 Oct;100(4):1172-3. doi: 10.1378/chest.100.4.1172. Chest. 1991. PMID: 1914588
-
Intratracheal pulmonary ventilation in a rabbit lung injury model: continuous airway pressure monitoring and gas exchange efficacy.Crit Care Med. 2000 Jul;28(7):2480-5. doi: 10.1097/00003246-200007000-00049. Crit Care Med. 2000. PMID: 10921582
-
Mechanical ventilator design and function: the trigger variable.Respir Care. 1992 Sep;37(9):1056-69. Respir Care. 1992. PMID: 10145700 Review.
-
Current Role of the Total Artificial Heart in the Management of Advanced Heart Failure.Curr Cardiol Rep. 2019 Nov 22;21(11):142. doi: 10.1007/s11886-019-1242-5. Curr Cardiol Rep. 2019. PMID: 31758343 Review.
Cited by
-
Ventilator autocycling and delayed recognition of brain death.Neurocrit Care. 2011 Apr;14(2):267-71. doi: 10.1007/s12028-010-9491-6. Neurocrit Care. 2011. PMID: 21222050
References
-
- Lloyd-Jones D, Adams R, Carnethon M, De Simone G, Ferguson TB, Flegal K, Ford E, Furie K, Go A, Greenlund K. Heart disease and stroke statistics -- 2009 update: a report from the American Heart Association Statistics Committee and Stroke Statistics Subcommittee. Circulation. 2009;119:480–486. doi: 10.1161/CIRCULATIONAHA.108.191259. - DOI - PubMed
-
- Hertz MI, Aurora P, Christie JD, Dobbels F, Edwards LB, Kirk R, Kucheryavaya AY, Rahmel AO, Rowe AW, Taylor DO. Registry of the International Society for Heart and Lung Transplantation: a quarter century of thoracic transplantation. J Heart Lung Transplant. 2008;27:937–942. doi: 10.1016/j.healun.2008.07.019. - DOI - PubMed
MeSH terms
LinkOut - more resources
Full Text Sources