High frequency oscillation in patients with acute lung injury and acute respiratory distress syndrome (ARDS): systematic review and meta-analysis
- PMID: 20483951
- DOI: 10.1136/bmj.c2327
High frequency oscillation in patients with acute lung injury and acute respiratory distress syndrome (ARDS): systematic review and meta-analysis
Abstract
Objective: To determine clinical and physiological effects of high frequency oscillation compared with conventional ventilation in patients with acute lung injury/acute respiratory distress syndrome (ARDS).
Design: Systematic review and meta-analysis.
Data sources: Electronic databases to March 2010, conference proceedings, bibliographies, and primary investigators.
Study selection: Randomised controlled trials of high frequency oscillation compared with conventional ventilation in adults or children with acute lung injury/ARDS. Data selection Three authors independently extracted data on clinical, physiological, and safety outcomes according to a predefined protocol. We contacted investigators of all included studies to clarify methods and obtain additional data. Analyses used random effects models.
Results: Eight randomised controlled trials (n=419 patients) were included; almost all patients had ARDS. Methodological quality was good. The ratio of partial pressure of oxygen to inspired fraction of oxygen at 24, 48, and 72 hours was 16-24% higher in patients receiving high frequency oscillation. There were no significant differences in oxygenation index because mean airway pressure rose by 22-33% in patients receiving high frequency oscillation (P</=0.01). In patients randomised to high frequency oscillation, mortality was significantly reduced (risk ratio 0.77, 95% confidence interval 0.61 to 0.98, P=0.03; six trials, 365 patients, 160 deaths), and treatment failure (refractory hypoxaemia, hypercapnoea, hypotension, or barotrauma) resulting in discontinuation of assigned therapy was less likely (0.67, 0.46 to 0.99, P=0.04; five trials, 337 patients, 73 events). Other risks were similar. There was substantial heterogeneity between trials for physiological (I(2)=21-95%) but not clinical (I(2)=0%) outcomes. Pooled results were based on few events for most clinical outcomes.
Conclusion: High frequency oscillation might improve survival and is unlikely to cause harm. As ongoing large multicentre trials will not be completed for several years, these data help clinicians who currently use or are considering this technique for patients with ARDS.
Comment in
-
High frequency oscillation in acute lung injury and ARDS.BMJ. 2010 May 19;340:c2315. doi: 10.1136/bmj.c2315. BMJ. 2010. PMID: 20484349 No abstract available.
Similar articles
-
High-frequency ventilation versus conventional ventilation for treatment of acute lung injury and acute respiratory distress syndrome.Cochrane Database Syst Rev. 2013 Feb 28;(2):CD004085. doi: 10.1002/14651858.CD004085.pub3. Cochrane Database Syst Rev. 2013. Update in: Cochrane Database Syst Rev. 2016 Apr 04;4:CD004085. doi: 10.1002/14651858.CD004085.pub4. PMID: 23450549 Updated.
-
High-frequency oscillatory ventilation versus conventional ventilation for acute respiratory distress syndrome.Cochrane Database Syst Rev. 2016 Apr 4;4(4):CD004085. doi: 10.1002/14651858.CD004085.pub4. Cochrane Database Syst Rev. 2016. PMID: 27043185 Free PMC article.
-
Positioning for acute respiratory distress in hospitalised infants and children.Cochrane Database Syst Rev. 2022 Jun 6;6(6):CD003645. doi: 10.1002/14651858.CD003645.pub4. Cochrane Database Syst Rev. 2022. PMID: 35661343 Free PMC article.
-
Recruitment manoeuvres for adults with acute respiratory distress syndrome receiving mechanical ventilation.Cochrane Database Syst Rev. 2016 Nov 17;11(11):CD006667. doi: 10.1002/14651858.CD006667.pub3. Cochrane Database Syst Rev. 2016. PMID: 27855477 Free PMC article.
-
Inhaled nitric oxide for acute respiratory distress syndrome (ARDS) in children and adults.Cochrane Database Syst Rev. 2016 Jun 27;2016(6):CD002787. doi: 10.1002/14651858.CD002787.pub3. Cochrane Database Syst Rev. 2016. PMID: 27347773 Free PMC article.
Cited by
-
High-frequency oscillation ventilation for hypercapnic failure of conventional ventilation in pulmonary acute respiratory distress syndrome.Crit Care. 2015 May 1;19(1):201. doi: 10.1186/s13054-015-0935-4. Crit Care. 2015. PMID: 25929255 Free PMC article.
-
Quantitative assessment of preoperative serum thyrotropin level and thyroid cancer.Oncotarget. 2016 Jun 7;7(23):34918-29. doi: 10.18632/oncotarget.9201. Oncotarget. 2016. PMID: 27166998 Free PMC article.
-
Moderately high frequency ventilation with a conventional ventilator allows reduction of tidal volume without increasing mean airway pressure.Intensive Care Med Exp. 2014 Dec;2(1):13. doi: 10.1186/2197-425X-2-13. Epub 2014 May 9. Intensive Care Med Exp. 2014. PMID: 26266914 Free PMC article.
-
Anti-Semaphorin-7A single chain antibody demonstrates beneficial effects on pulmonary inflammation during acute lung injury.Exp Ther Med. 2018 Mar;15(3):2356-2364. doi: 10.3892/etm.2018.5724. Epub 2018 Jan 8. Exp Ther Med. 2018. Retraction in: Exp Ther Med. 2023 Aug 14;26(4):466. doi: 10.3892/etm.2023.12165. PMID: 29456642 Free PMC article. Retracted.
-
High-frequency oscillatory ventilation in pediatric acute hypoxemic respiratory failure: disease-specific morbidity survival analysis.Lung. 2012 Dec;190(6):685-90. doi: 10.1007/s00408-012-9417-5. Epub 2012 Oct 5. Lung. 2012. PMID: 23053566 Free PMC article.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials