Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2010 Apr;43(4):283-91.
doi: 10.1111/j.1365-2591.2009.01678.x.

Laboratory evaluation of the physicochemical properties of a new root canal sealer based on Copaifera multijuga oil-resin

Affiliations

Laboratory evaluation of the physicochemical properties of a new root canal sealer based on Copaifera multijuga oil-resin

A D B Garrido et al. Int Endod J. 2010 Apr.

Abstract

Aim: To compare a new root canal sealer based on Copaifera multijuga oil-resin (Biosealer) using three other established sealers (Sealer 26, Endofill and AH plus) in terms of their physicochemical properties.

Methodology: The study was carried out according to the requirements of Specification Number 57 of the American Dental Association (ADA) and consisted of the following tests: setting time, flow, film thickness, dimensional stability, radiopacity and solubility/disintegration. Data were analysed statistically using anova and Tukey's test for multiple comparisons. The significance level was set at 5% for all analyses.

Results: Sealer 26 and AH Plus had the longest setting time (P < 0.05). All materials presented flow in with the ADA's guidelines. Regarding film thickness, Sealer 26 did not have a satisfactory performance, as it had a higher mean value than the maximum allowed by the ADA (0.05 mm), being significantly different from the other materials (P < 0.05), which had mean values for film thickness in accordance with the ADA's recommendations. Regarding the solubility and disintegration, only Endofill did not meet the ADA's specifications and presented the worst results of all materials (P < 0.05). Sealer 26 presented the greatest dimensional changes and differed significantly from all other sealers (P < 0.05). Biosealer had the lowest radiopacity values and was significantly different from the other sealers (P < 0.05).

Conclusion: The experimental sealer based on Copaifera multijuga oil-resin presented satisfactory results in the physicochemical tests required by the ADA.

PubMed Disclaimer

Publication types