Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2010 May;3(5):540-9.
doi: 10.1016/j.jcin.2010.01.015.

Impact of ultrasound attenuation and plaque rupture as detected by intravascular ultrasound on the incidence of no-reflow phenomenon after percutaneous coronary intervention in ST-segment elevation myocardial infarction

Affiliations
Free article

Impact of ultrasound attenuation and plaque rupture as detected by intravascular ultrasound on the incidence of no-reflow phenomenon after percutaneous coronary intervention in ST-segment elevation myocardial infarction

Mitsuaki Endo et al. JACC Cardiovasc Interv. 2010 May.
Free article

Abstract

Objectives: The aim of this study was to assess whether ultrasound attenuation and plaque rupture as detected by intravascular ultrasound (IVUS) are associated with the incidence of no-reflow phenomenon after percutaneous coronary intervention (PCI) for ST-segment elevation myocardial infarction (STEMI).

Background: No-reflow phenomenon is associated with worse long-term outcomes after STEMI. Therefore, reliable and feasible intravascular imaging techniques are needed to identify patient subgroups that would be at high risk for no-reflow phenomenon.

Methods: One hundred seventy consecutive patients with STEMI who underwent PCI within 12 h after symptom onset were enrolled. The IVUS interrogation was performed before PCI.

Results: No-reflow phenomenon occurred in 30 patients (18%), who had a higher incidence of no ST-segment resolution (50% vs. 9%; p < 0.001), a higher peak creatine kinase level (4,090 IU/l vs. 2,823 IU/l; p < 0.001), and a lower left ventricular ejection fraction in the chronic phase (51% vs. 59%; p < 0.01). Multivariate logistic regression analysis revealed that ultrasound attenuation with a longitudinal length of > or =5 mm, plaque rupture, and reperfusion time correlated with no-reflow phenomenon (all p < 0.05). In patients with both ultrasound attenuation > or =5 mm and plaque rupture, the incidence of no-reflow phenomenon was 88%, and the risk of decreased coronary reflow was higher than that predicted by either factor alone (p = 0.004 for interaction).

Conclusions: In patients with STEMI, a longer ultrasound attenuation and plaque rupture on IVUS are associated with an increased incidence of no-reflow phenomenon, suggesting that this subset of patients might be at high risk for distal embolism.

PubMed Disclaimer

Similar articles

Cited by

MeSH terms