. 2010 Jun;194(6):1658-63.
doi: 10.2214/AJR.09.3486.

False-positive findings at contrast-enhanced breast MRI: a BI-RADS descriptor study

Affiliations

False-positive findings at contrast-enhanced breast MRI: a BI-RADS descriptor study

Pascal A T Baltzer et al. AJR Am J Roentgenol. 2010 Jun.

Abstract

Objective: Breast MRI has high sensitivity in breast cancer detection, and the BI-RADS MRI lexicon was a step toward standardized description of lesions. However, false-positive findings occur and lead to unnecessary biopsy. The purpose of this investigation was to identify criteria for false-positive findings in clinical practice.

Materials and methods: Eligible for investigation were all breast MRI examinations from a consecutive 16-month time period that had histopathologic verification and findings classified as BI-RADS category 4-6 in the initial MRI report. Accordingly, 132 patients with 120 malignant and 31 benign lesions were enrolled. Two blinded observers categorized lesions into mass or nonmass and used BI-RADS to identify descriptor distribution differences between the benign and malignant subgroups.

Results: The ratio of mass to nonmass lesions differed significantly (p < 0.001) between benign (1.2:1) and malignant (7:1) findings. Seventeen mass and 14 nonmass lesions were false-positive, and 105 mass and 15 nonmass lesions were true-positive. Among mass lesions, it was possible to differentiate malignant and benign lesions on the basis of margin (smooth, irregular, or spiculated) and dynamic enhancement features (p < 0.05). Among nonmass lesions, only stippled enhancement had a significant difference between the subgroups (p < 0.05). Tumor diameter had no influence on the correct diagnosis of nonmass lesions (p = 0.301). Conversely, among mass lesions, false-positive lesions were smaller than true-positive lesions (p = 0.01).

Conclusion: Nonmass lesions were the major cause of false-positive breast MRI findings. BI-RADS descriptors are not sufficient for differentiating benign and malignant nonmass lesions.