A novel coronary artery bypass graft design of sequential anastomoses
- PMID: 20496004
- DOI: 10.1007/s10439-010-0068-5
A novel coronary artery bypass graft design of sequential anastomoses
Abstract
In this paper, the hemodynamics in a three-dimensional out-of-plane sequential bypass graft model is first investigated. Based on the advantageous flow characteristics observed within the side-to-side (STS) anastomosis in the sequential bypass graft simulation, a new CABG coupled-sequential anastomosis configuration is designed, entailing coupled STS and end-to-side (ETS) anastomotic components. In this new CABG design, the flow fields and distributions of various wall shear stress parameters within the STS and ETS anastomotic regions are studied, and compared to those of the conventional distal anastomosis, by means of computational fluid dynamics simulation of pulsatile Newtonian blood flow. Simulation results demonstrate that the new sequential anastomoses model provides: (i) a more uniform and smooth flow at the ETS anastomosis, without any stagnation point on the artery bed and vortex formation in the heel region of the ETS anastomosis within the coronary artery; (ii) a spare route for the blood flow to the coronary artery, to avoid re-operation in case of re-stenosis in either of the anastomoses; and (iii) improved distribution of hemodynamic parameters at the coronary artery bed and in the heel region of the ETS anastomosis, with more moderate shear stress indices. These advantages of the new design over the conventional ETS anastomosis are influenced by the occlusion ratio of the native coronary artery, and are most prominent when the proximal segment of the coronary artery is fully occluded. By varying the design parameters of the anastomotic angle and distance between the two anastomoses, the superior coupled STS-ETS anastomoses design is found to have the anastomotic angle of 30° and 30 mm distance between the two (STS and ETS) components.
Similar articles
-
In vitro measurements of velocity and wall shear stress in a novel sequential anastomotic graft design model under pulsatile flow conditions.Med Eng Phys. 2014 Oct;36(10):1233-45. doi: 10.1016/j.medengphy.2014.06.024. Epub 2014 Aug 4. Med Eng Phys. 2014. PMID: 25103345
-
Compliant model of a coupled sequential coronary arterial bypass graft: effects of vessel wall elasticity and non-Newtonian rheology on blood flow regime and hemodynamic parameters distribution.Med Eng Phys. 2012 Sep;34(7):860-72. doi: 10.1016/j.medengphy.2011.10.001. Epub 2011 Oct 26. Med Eng Phys. 2012. PMID: 22032834
-
Computational model of blood flow in the aorto-coronary bypass graft.Biomed Eng Online. 2005 Mar 4;4:14. doi: 10.1186/1475-925X-4-14. Biomed Eng Online. 2005. PMID: 15745458 Free PMC article.
-
High-frequency epicardial ultrasound: review of a multipurpose intraoperative tool for coronary surgery.Surg Endosc. 2009 Mar;23(3):467-76. doi: 10.1007/s00464-008-0082-y. Epub 2008 Sep 20. Surg Endosc. 2009. PMID: 18806944 Review.
-
Sutureless coronary anastomoses: revival of old concepts.Eur J Cardiothorac Surg. 2002 Oct;22(4):565-70. doi: 10.1016/s1010-7940(02)00378-0. Eur J Cardiothorac Surg. 2002. PMID: 12297173 Review.
Cited by
-
A predictive patient-specific computational model of coronary artery bypass grafts for potential use by cardiac surgeons to guide selection of graft configurations.Front Cardiovasc Med. 2022 Sep 27;9:953109. doi: 10.3389/fcvm.2022.953109. eCollection 2022. Front Cardiovasc Med. 2022. PMID: 36237904 Free PMC article.
-
Distal end side-to-side anastomoses of sequential vein graft to small target coronary arteries improve intraoperative graft flow.BMC Cardiovasc Disord. 2014 May 9;14:65. doi: 10.1186/1471-2261-14-65. BMC Cardiovasc Disord. 2014. PMID: 24884776 Free PMC article.
-
Numerical Assessment of Novel Helical/Spiral Grafts with Improved Hemodynamics for Distal Graft Anastomoses.PLoS One. 2016 Nov 18;11(11):e0165892. doi: 10.1371/journal.pone.0165892. eCollection 2016. PLoS One. 2016. PMID: 27861485 Free PMC article.
-
The study on hemodynamic effect of series type LVAD on aortic blood flow pattern: a primary numerical study.Biomed Eng Online. 2016 Dec 28;15(Suppl 2):163. doi: 10.1186/s12938-016-0252-4. Biomed Eng Online. 2016. PMID: 28155672 Free PMC article.
-
Effects of a carotid covered stent with a novel membrane design on the blood flow regime and hemodynamic parameters distribution at the carotid artery bifurcation.Med Biol Eng Comput. 2015 Feb;53(2):165-77. doi: 10.1007/s11517-014-1222-2. Epub 2014 Nov 5. Med Biol Eng Comput. 2015. PMID: 25370154
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical